Fike Vesda LaserCompact D1214

File Preview
File Preview
Click below to download for free

File Data

Name fike-vesda-lasercompact-d1214-7810243596.pdf
Type PDF
Size 1.37 MB
Downloads

Text Preview

OUTPUT MODULE MODULE MODULE MODULE MODULE 041 058 059 and Engineer Specification Listed LaserCOMPACT detector has been specifically designed to provide all the benefits of aspirating smoke detection including very warning in single environment small areas and where space is a premium This has been achieved through the combination of LaserPLUS detection technology dual stage air filtration technology and a modified aspirator design incorporated into a enclosure with a simplified display LaserCOMPACT is available in two versions one that interfaces via relays only RO or via relays and VESDAnet VN Reduced size Absolute smoke detection Wide sensitivity range Single pipe inlet Simple display Referencing VESDAnet communicaition VN Dual stage dust filter Three Alarm Levels Programmable Relays Air flow monitoroing Optional remote display and relay capability Simple mounting design AutoLearnTM front cover supports 5 LED Fault OK Reset Isolate Reset Isolate Push Button press to reset press and hold to isolate LaserCOMPACT is made up of two parts the main enclosure the front cover main enclosure houses all the key components of the detec All non serviceable items like the main processor board and chamber are mounted away from the general access area them during the installation and service process main enclosure includes Laser Detection Chamber Main processor board with integrated flow sensor card Single air inlet port with air flow monitoring device Termination Card supporting three relays including Service and Isolate The card also power connections and VESDAnet communi connection on the VN version LaserCOMPACT Aspirator Dual Stage Air Filter Cartridge Air Exhaust Port IT WORKS is continually drawn through a simple pipe network to a cen detector by a high efficiency aspirator Air entering the unit a flow sensor before a sample is passed through a dual dust filter the majority of air is exhausted from the detector hwere required back vented to the protected area The first removes dust and dirt from the air sample before it enters chamber for smike detection The second ultra fine stage pro a clean air supply to be used inside the detection chamber form clean air barriers which protect the optical surfaces from detection chamber uses a stable highly efficeint laser light and unique sensor configuration to achieve the optimum to a wide range of smoke types When smoke passes the detection chamber it creates light scatter which is by the very sensitive sensor circuitry status of the detector all alarms service and fault events are and logged with time and date stamps Status report can be transmitted via simple relay connections or across the VESDAnet communications network VN version only S 10th St P O Box 610 cid 127 Blue Springs MO 64013 0610 U S A cid 127 816 229 3405 cid 127 Fax 816 229 0314 cid 127 E mail fpssales fike com 2002 Issue LaserCOMPACT Specifications Termination Card VN Voltage 18 to 30VDC Comsumption quiescent 4.5W with alarm Consupmtion quiescent 19mA with alarm Rating 1.5A WHD 7 8 x 8 7 8 x 3 3 8 x 225mm x 85mm 4.3 lbs 1.9kg Temperature Ambient 14oF to 103oF 10oC to 39oC Air 4oF to 140oF 20oC to 60oC Network area of Coverage 5000 sq ft 500 sq m pipe length in accordance with Design Tool ASPIRETM and NFPA standards Diameter 9 16 7 8 15 21mm Diameter 1 25mm Relays rated 2A 30VDC Configuration Maintenance Isolate 0 60 seconds time delay for each relay Programmable Relays or non latching Rating IP30 Access TKO 4 x 25mm cable entries Range to 6 obs ft to 20 obs m Setting Range B Shield VESDAnet A VESDAnet A Shield VESDAnet B VESDAnet B Power Power Power Power A Bias GND Reset Reset Bias LED GND LED FIRE NO FIRE C PRE ALARM NO PRE ALARM C FAULT NO FAULT C FAULT NC A FIRE NO FIRE C PRE ALARM NO PRE ALARM C FAULT NO FAULT C FAULT NC B Bias GND Reset Reset Bias LED GND LED Power Power Power Power Termination Card RO Diagram Rear View 0.0015 0.6218 obs ft 0.005 to 1.990 obs m 0.0031 0.6234 obs ft 0.010 1.995 obs m 0.0046 to 6.25 obs ft 0.015 20.00 obs m to 4 obs ft for UL Features log Up to 12,000 events stored on FIFO level alarms and faults with time and date stamp Minimum 15 minutes maximum 15 days minimum 14 days AutoLearn thresholds are NOT changed from values Configurable General Purpose 24VDC AC Power OK and Reset Isolate Information VLC 505 VESDAnet Version VN VLC 500 Relays only Version RO VRT K00 Remote Display No Relay VRT J00 Remote Display 7 Relays 2 NO D1214 2002 by Fike Corporation All rights reserved PRINTED IN U S A on fractions cid 1 cid 2 1 16

Related Files