Gamewell-FCI NetSOLO Network
File Preview
Click below to download for free
Click below to download for free
File Data
Name | gamewell-fci-netsolo-network-6439750821.pdf |
---|---|
Type | |
Size | 644.50 KB |
Downloads |
Text Preview
NetSOLO Peer to peer token ring regenerative network operat Seismic Certified at 625K baud Up to 64 nodes in one network Built in isolation provides Style 4 Style 6 and Style 7 Two versions of INI 7100 module available using either wire INI 7100 UTP or both copper wire and cable INI 7100 FO Each node regenerates the signal to extend the another 3,000 feet 914.4 m of wire length or another 8 dB signal loss per fiber optic segment dB loss max Each 7100 Series fire alarm node supports up to 99 programming groups NetSOLO provides up to 125 network wide program groups The following 7100 features are available 63 programmable codes Cross zone programming between individual or between groups Output modules can be assigned to up to ten 10 Sequential restart delay Pre action deluge requires optional MCOM MEA 6911 1703 0116 US LISTED R Certificate Compliance 1 is a peer to peer token ring self regenerating using the 7100 Series fire alarm control panel to the highest degree of reliability flexibility and A NetSOLO application can consist of up to 7100 Series controls and provides a wide range of and network wide programming Features 7100 fire alarm control panel within the network will an Intelligent Network Interface module INI 7100 in its cabinet An INI 7100 module is easily con to its 7100 Basic System Module BSM via a plug ribbon cable A DIP switch on the INI 7100 module is to set the address the 7100 Series fire alarm control will occupy on the network types of INI 7100 modules are available The INI module unshielded twisted pair provides ter connections to 16 or 18 AWG conventional copper The INI 7100 FO fiber optic accommodates fiber cable ideal for connections running outside between as well as conventional wire INI 7100 module has the ability to regenerate the signal allowing maximum distances of up to feet between each node In the case of fiber optic a loss of up to 8 dB can be tolerated within any one of the network can be wired Style 4 Style 6 or Style 7 for maxi survivability In the event of the loss of communica each 7100 control panel has the ability to revert to its local programming 7100 Series fire alarm control panel retains all the of a standard 7100 panel providing two signaling circuits supporting up to 394 analog addressable two notification appliance circuits etc addition the network can be divided into regions Each can contain one or more 7100 panels is a registered trademark of Honeywell International Inc GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev K page 1 of 3 Continued of events within a particular region can be to just the alphanumeric LCD displays of the 7100 that are members of that region is useful for multiple building applications for exam where each building would constitute its own region 7100 Series fire alarm control panel in a network can designated as a global annunciator to annunciate from all network regions integral DACT on the 7100 2D can report events to a station from an individual panel within the network any panel within a region or serve as a global DACT the entire NetSOLO See P N 9020 0466 for details Specifications ft 914.4m max between nodes using 16 18 unshielded twisted pair copper wire cable Up to 200 microns optimized for microns 8 dB loss max between nodes Information Number Description Network Interface Unshielded Twisted pair Network Interface Fiber Optic Rev K page 2 of 3 Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 1 analog addressable line circuits with total of 196 addresses on each circuit annunciators LCD 7100 Max 5 display for all network events if set to Region 2 IV Ckts Printer for local or global event recording analog addressable line circuits with total of 196 addresses on each circuit annunciators LCD 7100 Max 5 or local display for all network or local only events if set to Region DACT to Central for local regional network events if wired Style 6 or 7 only to 64 analog addressable line circuits with total of 196 addresses on each circuit network annunciators Max 5 or local display for all network or local only events 3 analog addressable line circuits with total of 196 addresses on each circuit annunciators LCD 7100 Max 5 or local display for all network or local only events or local display for all network or local only events annunciators Max 5 or local display for all network or local only events analog addressable line circuits with total of 196 addresses on each circuit 5 analog addressable line circuits with total of 196 addresses on each circuit annunciators Max 5 4 IV Ckts 1 NetSOLO Configuration GAMEWELL FCI are for information only are not intended for installation purposes and are subject to change without notice No responsibility is assumed by Gamewell FCI for their use Clintonville Road Northford CT 06472 1610 USA Tel 203 484 7161 Fax 203 484 7118 by Honeywell International Inc All rights reserved www gamewell fci com Rev K page 3 of 3