Harrington Signal HFS-0257

File Preview
File Preview
Click below to download for free

File Data

Name harrington-signal-hfs-0257-3857421096.pdf
Type PDF
Size 661.21 KB
Downloads

Text Preview

HARRINGTON INC ALARM Tracker T8000 Alarm Control Panel Signal Inc 4th Avenue Moline Illinois 61265 Box 590 Moline Illinois 61266 0590 800 577 5758 Local 309 762 0731 Fax 309 762 8215 www harringtonfire com feedback which can be or disabled Design Learn Programming programmable through on Panel or Null Modem Cable interface via PC Peer to Peer up to 250 will have 250 system groups 250 network groups w optional module T NCA Printer Interface Non Modules can be remotely bus provides to modules Module T LCU 2 SLC s per module up to 4 T LCU for total of 8 Addressable provide Drift 8000 FACP FireSpy a modular design that can either addressable and or The basic unit be with 2 or 4 SLC circuits or 10 B 5Class A conventional zones or without a Dialer all installed in main FACP cabinet different combinations of cabinets the Tracker may expanded up to 8 SLC Circuits 60 Class B or zones Class A addressable module T LCU 2 SLC that can be for either I Spy XP95 addressable devices 126 per SLC or System Sensor devices 99 detectors modules T8000 programmed from the keypad the FACP or from a PC with the package Tracker T8000 FACP supports a AlarmCommunicator T UDACT that can be in the FACP enclosure or in remote enclosure The T UDACT either SIA or Contact ID to the Central Station The has a built in speaker for Information IR E A LARM have Flash Non Flash LED per Detector Verification Night Sensitivity Schedule for Schedule 20 days per year Intelligent support I Spy XP95 126 or System Sensor 198 protocol can be individual Protocol Module T CM 5 Class or 10 Class B zones per module Continued on Next Page Number Part Number Addressable SLC FACP Class A or B System Sensor I Spy XP95 Addressable SLC FACP Class A or B System Sensor I Spy XP95 w T UDACT Addressable SLC FACP Class A or B System Sensor I Spy XP95 Addressable SLC FACP Class A or B System Sensor I Spy XP95 w T UDACT FACP 10 Zones Class B or 5 Zones Class A FACP 10 Zones Class B or 5 Zones Class A w T UDACT T LCU Addressable SLC Bd in Exp Cabinet Class B or Class A System Sensor I Spy XP95 T LCU Addressable SLC Bd in Exp Cabinet Class B or Class A System Sensor I Spy XP95 Control Assembly includes chassis MCC PDC PC and power supply RL980 120VAC Loop Addressable SLC Board for Class B or Class A System Sensor I Spy XP95 Module Board w 10 Zones Class B or 5 Zones Class A Expander Cabinet for boards to be placed in remote locations holds 2 T LCU oards T SRM Board or T CM oard Information Continued on Next Page INC ALARM Tracker T8000 Alarm Control Panel Information Continued Number Part Number for T8 P U T8 P UD T8 P 2U T8 P 2UD T8 P C T8 P CD Module Bd in Expander Cabinet 10 Class B or 5 Class A w 1 T RC Board form C contacts can hold up to 5 T RC Relay Boards Board Expander Cabinet Only can hold up to 5 T RC Relay Boards T RC Relay Board in Expander Cabinet can hold up to 5 T RC Relay Boards or T NCA Expander Cabinet LCD Annunciator Board in Cabinet for the T2000 and T8000 Red Dialer Board SIA or Contact ID Module Board LCD Annunciator Board without Cabinet for T2000 and T8000 Boards w 2 Programmable Relays connects off the MCC or CM Module Boards is needed to 1st T RC board connection 5 board limit per connection Relay Module Board w 8 Programmable Relays Driver Module Board w up to 250 outputs LED or Lamps to connect T RC Board to the MCC Board or T CM Module Board 14 to connect T RC Board to the MCC Board or T CM Module Board 36 Annunciator Cabinet Only Special Order Hardware Kit for Expander Cabinets stand offs nuts screws Hardware Kit for T RC T UDACT T NCA Boards screws Programming Cable T2 P FACP T8 P FACP 15 Lock Key Modem Cable DB9F to DB9F 6 15 Key Only Continued up to 30 Class A or 60 Class B conventional zones 6 T CM boards per system Relay Module T SRM provides 8 programmable relay contacts supports 6 T SRM s for a total of 48 programmable relay contacts Driver Module T LDV provides up to 250 outputs to drive lamps may be LEDs or Incandescent bulbs 4 T LDV per FACP Remote annunciators T ANN per FACP reset programmable per each annunciator can be set up as latching non latching event can be set up as non reporting latching or non reporting non latching event Delay by Groups Walk Test Walk Test built in NAC output circuits rate at 3 Amps each and 7 Amps total per FACP outputs can be configured for Gentex Sync Protocol outputs can be configured as 24 VDC continuous or resettable power source outputs can be programmed as an Input dry contact circuit for Alarm Water Pull Station Supervisory Conditions Alarm Communicator Transmitter T UDACT Supports SIA and Contact ID Format has built on speaker with enable or disable feature for installation troubleshooting has unsent event log purge switch Series Only Excluding IS819 IS820 and System Sensor Series detectors Only INC ALARM Tracker T8000 Alarm Control Panel 8 5 NACs PC PRINTER straight cable BOARD ASS Y T8000 OR T2000 CONTACTS SYSTEM ALARM SYSTEM SUPV ALARM SYSTEM TROUBLE CONTACTS PER RC MAX LINES CENTRAL REMOTE NETWORK PER RC MAX CM MAX MAX MAX T8000 MAX T2000 MAX MAX PER LCU CLASS A OR ONLY CLASS B CM CONTACTS OUTPUTS PER SRM LDV TOTAL MAY BE INDIVIDUALLY CONFIGURED AS NAC AUX POWER OR INPUT SYSTEM MUST USE AT LEAST ONE INITIATING DEVICE INC ALARM Tracker T8000 Alarm Control Panel Specifications panel shall be a Harrington Signal FireSpy series Tracker T8000 modular type design with option of either addressable SLC s and or conventional zones with the option of adding on modules for user applications The Tracker T8000 shall support the following modules T LCU T CM T SRM T LDV T ANN and T NCA w EXP enclosure and or optional 10 zones conventional basic Tracker T8000 addressable panel zones conventional w EXP enclosure The basic system shall be capable of operating either py S XP95 series or System Sensor series addressable devices on the SLC s and expandable to of 2 SLC s expandable to T T LCU shall support either I S

Related Files