Honeywell Thermostat T834 User Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | honeywell-thermostat-t834-user-manual-1672490385.pdf |
---|---|
Type | |
Size | 1.44 MB |
Downloads |
Text Preview
Owner Manual Page 1 d Page 6 de Uso P 11 Series manual covers the following models Mount T8034N cid 127 Vertical Mount T834N T834L checklist package contents Thermostat Wall anchors screws 2 each you begin make sure you have No 2 Phillips small pocket screwdrivers Hammer Level optional Pencil Drill and bit 3 16 for drywall 7 32 for plaster be installed by a trained experienced technician Read these instructions carefully Failure to follow these instructions can the product or cause a hazardous condition ELECTRICAL HAZARD cause electrical shock or equipment damage Disconnect power before installation NOTICE this product is replacing a control that contains mercury in a sealed tube do not the old control in the trash Contact your local waste management authority for regarding recycling and proper disposal U S Registered Trademark Patents pending 2006 Honeywell International Inc rights reserved Series application thermostat provides control of 24 Vac single stage heating cooling systems Range 50 to 90 10 to 32 Ambient Temperature 0 to 120 18 to 49 Relative Humidity 5 to 90 non condensing vertical model 2.88W x 4.75H x 1.5D inches 73W x 121H x 38D mm horizontal model 4.75W x 2.88H x 1.5D inches 121W x73H x 38D mm Types Gas oil or electric heat with air Warm air hot water high efficiency heat pumps steam gravity Heat only Heat only with fan Cool only Settings Heat Off Cool T834N Off Cool T834L Settings Auto On Ratings 50 60Hz Running Current Heating Cooling Fan Cooling Heating Vac Vac Vac A A A Vac A Vac A Page 1 cid 127 Fran Page 6 cid 127 Espa P 11 installation Pull wires through wire hole base on wall level mark hole positions Drill holes 3 16 for drywall for plaster then tap in wall anchors Pull wire through base posi over anchors then insert tighten mounting screws level if desired Loosen screw terminals insert bare beneath screws then re tighten Push excess wire back into the wall Plug the wall opening with nonflam insulation to prevent drafts affecting thermostat operation Designations Heating power Connect to secondary of heating system transformer Cooling power Connect to secondary of cooling system transformer Fan relay Heat relay Heat pump changeover valve energized Heat pump changeover valve energized heating cooling Compressor contactor Not present in T834L model Rc terminals single transformer system leave metal in place between R Rc Remove jumper if two transformer system pump systems wiring to a heat pump use a small piece of not supplied to connect terminals W Y specifications 18 gauge thermostat wire Shielded is not required heat anticipator except model T834L Series fan switch except model T834L operation settings For gas or oil heating systems the fan operation switch in this position for systems that the fan in a call for heat Change the switch to this setting for pump or electric heat systems setting is for systems that allow thermostat to control the fan in a for heat if a fan wire is connected the G terminal the adjustment arrow to the setting for your system table below system water heat air high efficiency air standard heat mounting the slots on the cover with tabs on the of the base then push gently until the snaps into place Page 1 cid 127 Fran Page 6 cid 127 Espa P 11 switch On Fan runs continuously Auto Fan runs only when heating or system is on switch Cool Controls the cooling system Heat Controls the heating system Off All systems are off setting Adjust to set desired indoor temperature EQUIPMENT DAMAGE HAZARD Do not operate cooling system when temperature is below 50 10 limited warranty warrants this product to be free from defects in workmanship or materials under normal use and service a period of five 5 years from the date of purchase by the If at any time during the warranty period the prod is determined to be defective or malfunctions Honeywell repair or replace it at Honeywell option the product is defective return it with a bill of sale or other dated proof of pur to the place from which you purchased it or call Honeywell Customer Care at 1 800 468 1502 Care will make the determination whether the should be returned to the following address Return Goods Dock 4 MN10 3860 1885 Douglas Golden Valley MN 55422 or whether a replacement can be sent to you warranty does not cover removal or reinstallation This warranty shall not apply if it is shown by that the defect or malfunction was caused by which occurred while the product was in the of a consumer sole responsibility shall be to repair or the product within the terms stated above HONEY SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE ANY KIND INCLUDING ANY INCIDENTAL OR CONSE DAMAGES RESULTING DIRECTLY OR FROM ANY BREACH OF ANY WARRANTY OR IMPLIED OR ANY OTHER FAILURE OF THIS Some states do not allow the exclusion or of incidental or consequential damages so this may not apply to you WARRANTY IS THE ONLY EXPRESS WARRANTY MAKES ON THIS PRODUCT THE DURATION ANY IMPLIED WARRANTIES INCLUDING THE WAR OF MERCHANTABILITY AND FITNESS FOR A PURPOSE IS HEREBY LIMITED TO THE FIVE DURATION OF THIS WARRANTY Some states do not limitations on how long an implied warranty lasts so above limitation may not apply to you warranty gives you specific legal rights and you have other rights which vary from state to state you have warranty questions please write Honeywell Relations 1985 Douglas Dr Golden Valley MN or call 1 800 468 1502 In Canada write Retail ON15 02H Honeywell Limited Honeywell Limit Dynamic Drive Scarborough Ontario M1V4Z9 Manual Page 1 d Page 6 de Uso P 11 S ce manuel pour les mod suivants Horizontal T8034N cid 127 Mod Vertical T834N T834L n l le contenu de paquet Thermostat Chevilles et vis de montage de chaque et mat n Tournevis pointe cruciforme N 2 Petit tournevis de poche Marteau Niveau facultatif Crayon M 3 16 pour cloisons s 7 32 pour pl est imp de faire r l par un chevronn Lisez attentivement les pr consignes La non observation de risque d le produit ou de pr des dangers EN GARDE RISQUE provoquer des secousses ou endommager le mat Coupez avant d l CONCERNANT LE MERCURE ce produit remplace un dispositif de r contenant une ampoule de mercure placez pas ce dernier dans les ordures Contactez l de gestion des d la localit pour conna les r concernant le recyclage et la mise au rebut U S Marque d Brevets en instance 2006 Honeywell International Inc droits r