Honeywell Thermostat TH5220D1003 Manual

File Preview
File Preview
Click below to download for free

File Data

Name honeywell-thermostat-th5220d1003-manual-1542893067.pdf
Type PDF
Size 770.79 KB
Downloads

Text Preview

Downloaded from www Manualslib com manuals search engine Wiring Terminals on Thermostat of Unit TerminalsW2 2 stage ONLY GWCR HDS HDC PTS BTSW2GW1CRIgnition control in unit control compartment Wiring Terminals on Unit board on external junction boxPDP BDPGas valve high stage HI 3 or A F board on external junction boxDFG IFG DFP IFPGas valve high stage HI 3 or A Fan relay by others or to factory relay wire removed from T or HTGHTerminal board on external junction box Digit 13 4 Only DFG IFG DFP IFP DFS IFS HFG OFG HFP OFP3Factory time delay relay wire removed from 4421Terminal strip in control compartment Digit 13 0 1 2 or 3 6 436.9 5H76292A Honeywell TH5220D1003 thermostat wiring for gas unit heaters HD HDB HDS HDC PTS BTS PTC PDP BDP and duct furnaces seriesAugust 2009Wiring Diagram Selection For gas fired unit heaters and duct furnaces non factory supplied blower with model numbers shown above refer to Figure 1.1 and Table 1.1 for correct unit to thermostat wiring For all other system units factory supplied blower refer to the job specific unit wiring diagram provided with the unit For deviations to these wiring diagrams or the job specific wiring diagrams consult the factory Installation and WiringInstallation of wiring must conform with local building codes or in the absence of local codes of the National Electric Code ANSI NFPA 70 Latest Edition Unit must be electrically grounded in conformance to this code In Canada wiring must comply with CSA C22.1 Part 1 Electrical Code Figure 1.1 Terminals on Thermostat See page 2 for Thermostat Function Programming Instructions WARNING1 Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage 2 All units must be wired strictly in accordance with wiring diagram furnished with the unit Any wiring different from the wiring diagram could result in a hazard to persons and property 3 All wiring must be done with a wiring material having a temperature rating of at least 105 The use of this manual is specifically intended for a qualified installation and service agency All installation and service of these kits must be performed by a qualified installation and service agency 2 These instructions must also be used in conjunction with the Installation and Service Manual that originally shipped with the appliance in addition to any other accompanying component supplier literature Not all terminal connections are used Table only shows terminals that are used for required heating operation The factory installed R to Rc terminal wire jumper is to remain in place Verify that the buss bar on the G terminal is removed Verify that the buss bar between the T2 and F terminal is removed Table 1.1 Thermostat to Unit Wiringfirealarmresources com from www Manualslib com manuals search engine Products Group Modine Manufacturing Company 1500 DeKoven Avenue Racine Wisconsin 53403 2552 D H Model Series and Gas Fired Unit Heaters Phone 1.800.828.4328 HEAT Fax 1.800.204.6011 I O Model Series Phone 1.866.823.1631 Toll Free Fax 1.800.204.6011 Modine Manufacturing Company 2009 Litho in USA6 436.9Thermostat Function Program Selection To enter thermostat setup mode press and hold the s and FAN buttons until the display changes to setup mode Use the s and t buttons to change settings the NEXT button to advance to the next setting and the DONE button to save the settings and exit from the setup mode For gas fired unit heaters and duct furnaces non factory supplied blower with model numbers shown on the opposite side refer to Table 2.1 typical thermostat function settings For all other system units factory supplied blower refer to the job specific unit wiring diagram provided with the unit For deviations to these wiring diagrams or the job specific wiring diagrams consult the factory For additional information refer to the vendor literature supplied with the thermostat Table 2.1 Typical Thermostat Function Program Settings 2.1 Buttons to Press to Enter Function Programming ModeFunction NumberFeatureTypical SettingDescription1System type3Single stage heat only with fan62 heat 2 cool conventional cooling by others 72 heat 1 cool conventional cooling by others 3Fan control0Gas or oil furnace equipment controls fan in heating5Heat cycle rate CPH 5For gas or oil furnaces of less than 90 efficiency3For furnaces of over 90 efficiency6Second stage heat cycle rate CPH 5For gas or oil furnaces of less than 90 efficiency3For furnaces of over 90 efficiency9 12Cooling functions display0Fahrenheit1Celcius15 26Cooling and emergency heat functions temperature range stops90Default value can be set 40 90 in increments of 1 PTC models this setting must be changed to 8028Cool temperature range stops50 See Honeywell instructions that shipped with stat for more information and additional setting options Press and hold to enter function programming modefirealarmresources com

Related Files