Mircom CAT-5960 MS-700MP(U) Series Data Sheet (English)

File Preview
File Preview
Click below to download for free

File Data

Name mircom-cat-5960-ms-700mp-u-series-data-sheet-english-5426190387.pdf
Type PDF
Size 1.12 MB
Downloads

Text Preview

FIRE ALARM MANUAL STATIONS SERIES High quality die cast metal Attractive Low Profile Design Built in intelligent addressable module with Mircom Pulling the handle initiates the operation of the intelligent Address is set by the MIX 4090 hand held device Two stage and single stage dual action version UL and ULC listed version Standard Single Gang Mount Device comes with reset key and plastic rod MS 700MP U Series Fire Alarm Manual Stations manual fire alarm activation These pull stations are as single or dual action devices They are reset with key Each station has a permanently attached MP Mircom addressable module with FX 400 series and FleX Net MP Fire Alarm Panels MS 700MP Manual stations are constructed of high die cast metal and finished in red An abrasion label with large raised letters provides clear instructions is done using the MIX 4090 Device programmer model MS 702MP is the Intelligent Key Resettable Two Manual Station model MS 710MP U is the Intelligent Key Resettable Stage Dual Action Manual Station Suffix indicates a USA version manual fire alarm stations shall be installed as per the requirements outlined in the UL ULC codes as as all other applicable national or local codes the alarm On the MS 702MP pull down the PULL handle On the MS 710MP U push in the PUSH bar then pull the PULL handle the stage two alarm MS 702MP only Insert the stage two key into the keyhole above the PULL and then turn the key The stage two alarm activates immediately the manual station Open the station with the reset key The switch is now Move the PULL handle back to its upright position Close and lock the station Resetting the station does not cancel the alarm at the TO BE USED FOR INSTALLATION PURPOSES INFORMATION IS FOR MARKETING PURPOSES ONLY AND INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY NUMBER Operating Voltage Alarm Current current H x 3.56 W x 2.56 D H x 3.56 W x 2.9 D VDC mA mA Diagram Diagram STATION GANG NEXT STATION OR OF LINE DEVICE BLACK RED Information Key Resettable Two Stage Manual Station MP ULC Key Resettable Single Stage Dual Action Manual Station MP ULC Key Resettable Single Stage Dual Action Manual Station MP UL Device Programming Tool Junction Box for Indoor Surface Mount Red Junction Box for Outdoor Surface Mount Red Plastic Rod Interchange Way Ontario L4K 5W3 905 660 4655 905 660 4113 Witmer Industrial Estates Falls NY 14305 Free 888 660 4655 Toll Free 888 660 4113 INFORMATION IS FOR MARKETING PURPOSES AND NOT TO DESCRIBE THE TECHNICALLY complete and accurate installation testing and certification refer to technical This document contains intellectual property of Mircom information is subject to change by Mircom without notice does not represent or warrant correctness or completeness relating 5960 2

Related Files