Notifier AM2020-AFP1010 Operating Instructions Rev D

File Preview
File Preview
Click below to download for free

File Data

Name notifier-am2020-afp1010-operating-instructions-rev-d-3908725614.pdf
Type PDF
Size 950.41 KB
Downloads

Text Preview

and AFP1010 Fire Alarm Control Panel Operator Instructions and mount these Operator Instructions adjacent to the AM2020 for ready reference Display Interface Assembly DIA 1 DIA 2 Display Interface Assembly DIA 1 DIA 2 Display Interface Assembly DIA 1 DIA 2 Display Interface Assembly DIA 1 DIA 2 Display Interface Assembly DIA 1 DIA 2 Power Alarm Trouble Trouble Silence Sounder SILENCE RESET TEST TEST green LED will illuminate to indicate that the system operating from the primary power supply red LED will flash to indicate that the panel has at least one alarm condition in the system red LED will light steadily when all alarms have acknowledged The panel display will provide information on any alarms received yellow LED will flash to indicate any unacknowl change of status in the system The panel will provide detailed information on the first change of status received After change of status conditions have been acknowledged and while at least one condition still exists the SYSTEM TROUBLE LED will illuminate steadily yellow LED will illuminate when panel has detected a trouble condition in the display assembly yellow LED will illuminate steadily when all control modules in the system which can silenced have been silenced A flashing yellow LED indicates a partial signal condtion some of the control modules that can be silenced have been local panel piezo sounder provides an audible indication of the system alarm trouble conditions The sounder will pulse when the system is in alarm and will steadily when the system is in trouble The sounder is silenced when all have been acknowledged If the sounder sounds steadily and it cannot silenced by the acknowledgement of all system alarm trouble conditions CALL SERVICE REPRESENTATIVE IMMEDIATELY This sounder will also pulse whenever a keypad key is depressed key is used to acknowledge system alarm or trouble conditions When the operator acknowledges the new status of the device indicated on the Depression of this key will also step the display to the next device in alarm trouble After all such system alarm and trouble conditions have been acknowl the ACK STEP switch may be used to step the display through the exisitng alarm and trouble conditions key will deactivate all activated control modules that have been programmed permit signal silencing key is used to clear all system alarm and trouble conditions If an alarm or trouble still exists after SYSTEM RESET that alarm trouble condition will resound key is used to automatically perform a test of all intelligent detectors in the Results of the system detector test are then indicated on the panel expander AEM 16AT or AEM 32A this switch serves as a monitor TEST only key is used to perform a test of LEDs on the control panel and to test the LCD The test will illuminate the panel LEDs in sequence for a timed period and the LCD display When the test has been completed the panel LEDs and the will return to their prior states O and ACM 32A Annunciators and ACM 32A Annunciators and ACM 32A Annunciators and ACM 32A Annunciators and ACM 32A Annunciators Trouble Line yellow LED illuminates to indicate a trouble in the AM2020 green LED flashes to show that the annunciator is with the AM2020 Local Silence Acknowledge Switch lights all the LEDs on ACM 16AT and acknowledges all status changes for both the and the expanders Flashing LEDs on the annunciator latch on solid and the piezo sounder will be silenced NOTE LEDs only red LED associated with each point will flash or illuminate steadily to indicate of that point alarm or energization The yellow LED associated with each point will flash or illuminate steadily to indicate a trouble condition on that ACM 16AT or AEM 16AT only circuits The control switch serves as an Acknowledge for this point Pressing control switch after the onset of a trouble condition will cause the flashing yellow LED to illuminate steadily circuits The control switch does not serve as an Acknowledge for this point the control switch toggles the state of the output circuit if the circuit is ON the switch turns the circuit OFF and vice versa Zones The control switch serves as an Acknowledge for the software 15555 Rev D 4 30 91 Level Call Line CALL SWITCH VOLUME Circuit Select only Select Select only Audio Message Generator Audio Message Generator Audio Message Generator Audio Message Generator Audio Message Generator green LED is illuminated when the audio is correct When paging talk loudly enough cause this LED to illuminate If the AUDIO LED is allowed to remain off for 30 seconds system trouble will result green LED toggles on and off with each of the ALL CALL SWITCH green LED indicator is normally illuminated show that the AM2020 is communicating with Audio Message Generator yellow LED illuminates to indicate the of a trouble in local audio subsystem AMG AA 30 FFT 7 All Call Switch when pressed can be used to activate all speaker circuits a specific programmed group of speakers These speaker circuits will when the All Call Switch is pressed again toggle function providing alarm is not present If an alarm is present the speaker circuit will remain until manually turned off or until the system is reset For dual channel either All CALL switch can be pushed Local Speaker Volume control adjusts the volume of the speaker located the AMG It will not affect the volume of the speakers installed throughout the If neccessary turn the volume down to prevent feedback during paging microphone is used for paging To page select the speaker circuit s that wish to page through by using the control switches on ACM 16AT Annunciators by using the All Call Switch Depress switch on side of microphone and speak the microphone Talk loudly enough to cause the green Audio Level LED to turn a speaker circuit ON press the control switch on the annunciator point to that speaker circuit The red LED on the point selected will illuminate control switch toggles the state of its circuit If the speaker circuit has been activated automatically by the AM2020 pushing the control switch will the yellow LED on the annunciator point and the AM2020 Signal Silence to flash indicating that a partial silence has been effected select an audio output function voice message or audio tone press the switch on the annunciator Note An active audio function may have to be before selection of the next function select a channel press the control switch on the annunciator point mapped the desired channel The RED LED on that point will illuminate The control toggles the selection of the channel Channels must be selected for each zone in a dual chanel system Audio Tone Generator Audio Tone Generator Audio Tone Generator Audio Tone Generator Audio Tone Generator ATG 2 provides user selected tones for single or dual channel output The ATG 2 generates either a whoop Hi Lo or steady tone on the primary EVAC channel In dual channel operation the ATG 2 also either a chime or a 20 pulses per minute tone on the secondary ALERT channel Line Channel Channel SELECT green LED indicator is normally illuminated show that the AM2020 is communicating with Audio Tone Generator green LED illuminates to show that will occur over the EVAC channel green LED illuminates to show that will occur over the ALERT channel yellow LED illuminates to indicate the of a trouble in local audio subsystem AMG AA 30 FFT 7 Page Select Switch when pressed is to choose between EVAC and ALERT for paging The respective LED will illuminate when that channel has selected microphone is used for paging To page select the desired channel by the PAGE SELECT SWITCH until the respective LED illuminates switch on side of microphone and speak into the microphone Mode Line Trouble Trouble Switch Calls Fire Fighters Telephone Fire Fighters Telephone Fire Fighters Telephone Fire Fighters Telephone Fire Fighters Telephone green LED illuminates when the MODE SWITCH is depressed

Related Files