Notifier N-ANN-RLY Data Sheet

File Preview
File Preview
Click below to download for free

File Data

Name notifier-n-ann-rly-data-sheet-8394126705.pdf
Type PDF
Size 836.73 KB
Downloads

Text Preview

N ANN RLY Relay Module N ANN RLY relay module provides 10 programmable Form C when used with a compatible FACP Fire Alarm Control The N ANN RLY module may be mounted inside the FACP circuit board chassis or in the battery area of the enclosure optional mounting bracket P N ANN MBRLY Reference Instructions document 53318 N ANN RLY and the FACP communicate over a two wire serial employing the ANN Bus communication format An addi two wires are used for 24 volt DC power A single four con unshielded cable may be used for both power and data to eight ANN Bus devices may be connected to the ANN Bus of FACP N ANN RLY connects to the ANN Bus terminal on the FACP and minimal programming Provides 10 programmable Form C relays Ten Form C relays can be programmed for various functions Trouble Supervisory AC Loss Waterflow Delay Input and Silenceable Alarm Compatible with the NFW 100X NFW 50X NFW2 100 C NFW RP 2001 C RP 2002 C SFP 10UD C and SFP May be powered by 24 VDC from the host FACP or by remote supply requires 24 VDC Up to eight ANN Bus devices may be connected to the ANN Bus each FACP Listed to UL Standard 864 9th Edition Maximum ANN BUS Voltage 24 VDC Maximum Current Alarm 75 mA Standby 15 mA Ambient Temperature 32 to 120 0 to 49 Relative Humidity 93 2 RH non condensing at 32 2 3 For use indoors in a dry location Connections to FACP are power limited and supervised Relay Contact Ratings 2 Amps 30VDC Resistive 0.5 Amps 30VAC Resistive ANN Bus THE DEVICES ON THE ANN BUS FROM AUXIL POWER SUPPLY devices can be powered by an auxiliary power supply available panel power is exceeded See FACP manual for DEVICE ADDRESSING ANN Bus device requires a unique address ID Number in to communicate with the FACP A maximum of eight devices be connected to the FACP ANN Bus communication circuit See FACP manual for more information Information N ANN RLY Relay Module provides 10 programmable Form C ANN MBRLY Optional mounting bracket applications ROME Relay Option Module Enclosure includes one ANN RLY module and one ANN MBRLY bracket installed Listings and Approvals listings and approvals below apply to the FeaturedProduct In cases certain modules may not be listed by certain approval or listing may be in process Consult factory for latest list status UL S635 FM Approved Fire Dept of New York COA 6177 CSFM 7120 0028 0259 MEA 333 07 E 3 15 2018 Page 1 of 2 Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized of this document is strictly prohibited of Origin USA

Related Files