N ANN S PG Serial Parallel Printer Interface Module N ANN S PG Interface module connects either a serial or paral printer with a compatible Fire Alarm Control Panel FACP to print logs of system events detector status reports and event N ANN S PG and the FACP communicate over a two wire interface employing the ANN Bus communication format An two wires are used for 24 volt DC power A single four unshielded cable may be used for both power and data to eight devices may be connected to the ANN Bus of each Listed to UL Standard 864 9th edition Auto configure menu selection allows programmer to bring all the attached to the ANN Bus on line quickly Surface mounts directly to wall Can be remotely located up to 6,000 feet 1,829 m from the May be powered by 24 VDC from the host FACP or by remote supply requires 24 VDC Connects a remote printer using a standard cable DB 9 for a printer DB 25 for a parallel printer Operating Voltage 24 VDC Current Alarm and Standby 45mA Ambient Temperature 32 to 120 0 to 49 Relative Humidity 93 2 RH non condensing at 32 2 Maximum wiring distance from FACP 6,000 ft 1,829 m Dimensions 6.00 15.2 cm high x 7.76 19.7 cm wide x 1.46 3 cm deep For use indoors in a dry location Connections to FACP are power limited and supervised ANN Bus THE DEVICES ON THE ANN BUS FROM AUXIL POWER SUPPLY devices can be powered by an auxiliary power supply available panel power is exceeded See FACP manual for DEVICE ADDRESSING ANN Bus device requires a unique address ID Number in to communicate with the FACP A maximum of eight devices be connected to the FACP ANN Bus communication circuit See FACP manual for more information Listings and Approvals listings and approvals below apply to the N ANN S PG In some certain modules may not be listed by certain approval agen or listing may be in process Consult factory for latest listing UL S635 CSFM 7120 0028 0242 MEA 442 06 E Vol 2 3 15 2018 Page 1 of 2 Clintonville Road CT 06472 document is not intended to be used for installation purposes try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized of this document is strictly prohibited of Origin USA

Related Files