Notifier N-MPS and NFW-MPS Addressable Series Manual Stations
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-n-mps-and-nfw-mps-addressable-series-manual-stations-9347806152.pdf |
---|---|
Type | |
Size | 757.76 KB |
Downloads |
Text Preview
N MPS and NFW MPS Series Stations Notifier MPS Addressable Series manual stations provide for the NFS 320C NFS2 640 and NFS2 3030 fire control panels NFW MPS series manual stations provide for FireWarden series panels These high quality die metal manual stations include screw terminal connections integrated break glass rod The alarm contact for the man station is rated for 1A 24VDC The contacts are gold plated avoid the risk of corrosion MPS Series manual stations are available as single or two for addressable systems Models N MPS SA SAC are sin manual stations Models N MPS 2AC 2A two stage are similar to the N MPS SC single stage models they contain an additional 2nd Stage normally open key A 2nd stage key is supplied with each unit to activate the Stage key switch models are available with screw terminal connectors and a key for reset Two stage models also include a key switch 2 keys All addressable models require an additional trim sold separately to mount on a 4 electrical box RMS or a 2 gang electrical box RMS TP1 with a minimum of 5.5cm 2.125 All addressable models can mount to a gang electrical box for retrofit situations when used with extension ring MPS ER sold separately surface mounting use Notifier surface back box with all manual stations Notifier MPS Series manual stations are operated by pulling handle on the front of the station To reset the manual sta open the manual station with the hex key provided and the handle in the normal upright position Replace the rod and close the manual station front cover N MPS two stage models include a key switch which is above the handle Operation of the key switch when to a separate alarm initiating circuit will activate the stage of a two stage alarm signaling system reset the second stage activation return the key switch to the position before resetting the fire alarm control panel provided with an ancillary contact for mag lock release simultaneously release the locally connected mag lock upon the handle on the front of the manual station Constructed of high quality die cast metal Highly visible red enamel finish English and French lettering Single action pull lever design Optional dual action lever kit Hex key resettable Screw terminal connectors Optional ancillary contact for local mag lock release Single stage and two stage models Key switch activation for second stage Fully addressable using Flashscan or CLIP technology Single stage addressable manual stations require one break glass on a data communications link DCL circuit DN 60629 A1 Addressable Initiating Devices Two stage addressable manual stations on a data communications link DCL circuit Surface or semi flush mounting All addressable models mount on a standard 4 square elec box or a two gang electrical box with suitable semi flush plate sold separately All addressable models can mount to a single gang electrical for retrofit situations when used with an extension ring sold separately manual station is the Notifier N MPS series Operating appear in English and French lettering The unit is of high quality die cast metal and finished in red paint to be easily identified When the handle is pulled manual station initiates an immediate operation of the alarm circuit In addition those manual stations installed in a system are equipped with a key switch designed to the second stage alarm initiating circuit Manual stations have the option of an ancillary contact for local mag lock Manual stations are listed with Underwriters Laborato Canada ULC Manual stations are required to be installed the current Canadian Electrical Code and the current CAN S524 Standard for the installation of Fire Alarm Sys and comply with CAN ULC S528 Manual Stations for Alarm Systems Including Accessories Manual stations be installed within the limits defined by the national local Final acceptance is subject to the local authority jurisdiction stations are provided with a hex key reset lock reset the device after the manual station has been operated to allow access for testing The stations are designed so after an actual emergency operation the stations cannot be to normal operation without the use of the supplied hex DN 60629 A1 06 22 2010 Page 1 of 2 Addressable two stage manual station English lettering Addressable two stage manual station English lettering For use with FireWarden panels Addressable two stage manual station N C ancil contact included English French lettering Addressable two stage manual station N C contact included English French lettering For use with panels conventional manual stations see DN 5497 Lift pull dual action adapter cover for use with the Series manual stations English French lettering Mounting plate for semi flush mounting addressable stations to a 4 square electrical box red Mounting plate for semi flush mounting addressable stations to a two gang electrical box red Deep surface back box for use with addressable 123.83mm H x 82.5mm W x 57.2mm D 4.88 H x x 2.25 D Extension ring for addressable models using existing electrical boxes Replacement break glass rods Package of 10 Replacement Hex Key Replacement 2nd Stage Key The manual stations are provided with an integrated break feature addition of the dual action adapter cover MPS LP requires operator to first lift the cover and then pull the handle of the station addressable models require an additional trim plate to mount a 4 electrical box or a two gang electrical box both with a depth of 5.5cm 2.125 Addressable models can to a single gang electrical box for retrofit situations when with an extension ring MPS ER surface mounting use Notifier surface back box MPS DBB all addressable manual stations models will have screw terminal connectors for to the fire control panel data communications link The address of the manual station is selected through use of two rotary decimal switches Listings and Approvals ULC listed S7568 121mm H x 82mm W x 61mm D 4.75 H x W x 2.40 D Operating Voltage 24.0 VDC DCL Voltage 32.0 VDC DCL Current Single stage 550 Two stage Temperature 32 to 120 0 to Humidity 93 2 RH non con at 32 2 90 3 Connections 18 to 12 AWG Red with white bilingual White pull bar with red letters MODELS WITH ANCILLARY Contact Ratings 30 VAC 6 amps Resistive 6 amps Inductive 30 VDC 6 amps Resistive 3 amps Inductive All models are for use indoors in a dry Line Information MANUAL STATIONS Addressable single stage manual English French lettering Addressable single stage man station English French lettering For use FireWarden panels Addressable single stage man station N C ancillary contact included lettering Addressable single stage station N C ancillary contact included lettering For use with FireWar panels Screw terminals not shown are located behind addressable modules and FlashScan are registered Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited of Honeywell document is not intended to be used for purposes We try to keep our prod information up to date and accurate We cover all specific applications or anticipate requirements All specifications are subject to without notice more information contact Notifier 289 1114 Whitmore Road Ontario L4L 7Z4 2 of 2 Canadian DN 60629 A1