Notifier N100-ISO(A) Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-n100-iso-a-data-sheet-5896310742.pdf |
---|---|
Type | |
Size | 681.07 KB |
Downloads |
Text Preview
N100 ISO A Isolator Module FireWarden Series Panels NOTIFIER N100 ISO A Fault Isolator Module is used FireWarden Series panels to protect the system against short circuits on the SLC loop The N100 ISO A be placed between each device on the SLC loop to iso a short circuit problem between the modules It is required true Style 7 operation so that other devices can continue to normally in the event of a short circuit on the SLC Powered by SLC loop directly no external power required Mounts in standard junction boxes 4.0 10.16 cm square cm deep LED blinks to indicate normal condition Illuminates when short circuit condition is detected High noise EMF RFI immunity Fault Isolator Modules should be spaced between groups sensors in a loop to protect the rest of the loop Use to iso short circuit problems within a section of a loop so that sections can continue to operate normally The N100 supports a maximum of 25 devices in between isola except when using relay bases LOADS PER RELAY BASE AND ISOLATORS ISOLATOR The maximum number of addressable devices between or B224BIA isolator bases is 25 devices DEVICES base base relay bases draw more current than other intelligent When calculating the 25 device maximum B224RB rep 2.5 DEVICES see example on page 2 ON MAXIMUM NUMBER OF DEVICES See the SLC 52304 for information on loss of addresses due to current Each module or base added reduces the capacity of positions in an SLC All SLC field devices must have been after February 1995 to meet the aforementioned If the SLC field devices were purchased prior to 1995 each isolator used reduces the capacity of an SLC two address positions Requirements differ as applied to relay see note above Operating voltage 15 32 VDC peak Maximum current upon activation due to short circuit to the manual for the main FACP relay closed Temperature range 32 to 120 0 to 49 Relative humidity 10 to 93 Weight 5 oz 150 grams A1 370 Dimensions 4.5 x 4.5 x 0.25 D 11.43 cm H x cm W x 0.635 cm D face plate is made of off white plastic Module includes LED indicator that pulses when normal and illuminates when a short is detected opens circuit when the line voltage drops below volts Fault Isolator Modules should be spaced between of addressable devices maximum 25 see notes on 1 in a loop to protect the rest of the loop If a short between any two isolators then both isolators immedi switch to an open circuit state and isolate the groups of between them The remaining units on the loop con to fully operate Style 4 loops the N100 ISO A is generally used at each T branch to limit the effect of short circuits on a branch to the on that branch The LED indicator is on continuously a short circuit condition N100 ISO A Fault Isolator Module automatically restores shorted portion of the communications loop to normal Mount on a standard junction box 4.0 10.16 cm square Terminal screws are provided for and out wiring Surface mount box is available as an option instructions are provided with each module 01 05 2012 Page 1 of 2 Standby current 450 cid 2 A maximum N100 ISO A is not is at least 2.125 5.398 cm deep Specifications Isolator Modules shall be provided to automatically iso wire to wire short circuits on an SLC loop The Fault Isola Module shall limit the number of modules or detectors that be rendered inoperative by a short circuit fault on the SLC If a wire to wire short occurs the Fault Isolator Module automatically open circuit disconnect the SLC loop the short circuit condition is corrected the Fault Isolator shall automatically reconnect the isolated section of SLC loop The Fault Isolator Module shall not require any and its operations shall be totally automatic It not be necessary to replace or reset an Fault Isolator after its normal operation The Fault Isolator Module mount in a standard 4 10.16 cm deep electrical box in surface mounted backbox or in the Fire Alarm Control It shall provide a single LED which shall flash to indi that the Isolator is operational and shall illuminate steadily indicate that a short circuit condition has been detected and Approvals and Listings listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in progress Consult factory for listing details UL Listed S635 CSFM 7300 0028 0238 MEA 427 91 E Vol 9 FM Approved Line Information suffix indicates ULC Listed model Isolator module Same as N100 ISO with ULC Listing Optional surface mount backbox of Device Counts notes under Applications base as with base with base Count base than 25 total is a registered trademark of Honeywell International Inc and FireWarden are registered Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited of Honeywell document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 in the U S A 2 of 2 DN 6994 B 01 05 2012