Notifier NFV-25 50ZS FireVoice-25 50 Zoned System Voice Evacuation Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

NFV 25 50ZS Zoned System Evacuation Control Panel FireVoice 25 50 Zoned System NFV 25 50ZS a state of the art Emergency Voice Evacuation Panel capable of splitting 25 or 50 watts of audio power into to eight speaker circuits i e zones The NFV 25 50ZS five field programmable messages up to 60 seconds message duration with an integral commercial grade communications microphone or from an external source Significant technological enhancements set the apart from other EVAC panels these include supervision in both active alarm and standby conditions of amplifier outputs field wiring message genera all tone generators and the microphone The integral supply is capable of charging up to 18 AH batteries can be housed in the NFV 25 50ZS cabinet NFV 25 50ZS is suitable for use as an adjunct slave or to most UL Listed Fire Alarm Control Panels An optional 25 watt 25 Vrms audio amplifier to 50 watts or as a secondary amplifier in jurisdictions backup A 70.7 Vrms converter is also available for converting amplifiers to meet retrofit needs Zone Splitter Module ACC ZSM divides the output of the Amplifier Module s ACC AAM25 into up to eight circuits i e zones The Zone Page Module with Key ACC ZPMK provides full manual control of the speaker status indication of each of the speaker circuits and control by the FACP via the ACS serial link connec host of field programming options including the capability of custom messages fire tornado evacuation hazmat non multi language etc make the NFV 25 50ZS the most ver voice evacuation system available applications include schools auditoriums dormito theaters restaurants places of worship lodging offic e and factories Listed to UL Standard 864 9th edition 25 watts of audio power can be divided into eight Style Y B or four Style Z Class A speaker circuits zones the zone splitter module ACC ZSM Full manual control of all audio zones provided by zone module with keypad ACC ZPMK Activation by the FACP using the ACS serial link and or the Command CMD inputs ACS serial link activation with compatible NOTIFIER such as NFW2 100 NFS 320 and NFS2 640 CMD activation compatible with any FACPS FACP automatically directs the voice message to each or all Paging by zone or All Call Full status indication normal active fault of each speaker zones Fault indication via ACS serial link and or the two Form C relays System and AC Power Loss C 15 Control Systems 25 watt 25 Vrms audio amplifier with single Style Z A or Style Y Class B speaker circuit expandable 50 watts using the ACC AAM25 Modular design for maximum system flexibility and ease of Two command input circuits can be independently field pro for activation by a Notification Appliance Circuit or contact closure Three command input circuits activate on contact closure ACS link or Command Input CMD control of One 60 second message Two 30 second messages Three 20 second messages Four 15 second messages Five 12 second messages Microphone time out feature Nineteen different system and diagnostic LEDs Optional equipment second amplifier playback remote microphone and paging equipment inter digital message generator with standard factory emergency evacuation message Custom messages are field recordable without the addition costly add on modules utilizing the integral microphone the audio input jacks Digital message may be field selected for 3 4 6 8 or infi repeat Built in alert tone generators with steady slow whoop high or chime tone capability Field selectable lead in trailing tone selection 1 14 10 Page 1 of 4 Alert tone selection may be field programmed to conform ANSI S3.41 Audible Emergency Evacuation Signal Pattern per NFPA Speaker zone control via ACS serial link CMD inputs or Dual optically isolated trigger input circuits are indepen field programmable for activation by polarity reversal FACP NAC or dry contact closure diagnostic LEDs include Power System Trouble Trouble Message Generator Trouble Tone Trouble Amplifier Fault and others ACS serial link or independent Form C trouble relay allows to monitor voice system while in active alarm state piezo provides local audible indication for troubles Fully supervised in Standby and Active states including microphone amplifier output message generator wiring and tone generators amplifier supervision current limit audio level circuit protection All outputs are power limited Auxiliary power output provides local power for addressable modules when used to activate the NFV 25 50ZS Compatible with all NOTIFIER FACPs as well as other panels Modules 25 watt 25 Vrms audio amplifier module Field programmable for system expansion to 50 watts or as backup to the primary 25 watt amplifier where required Single Class A or Class B speaker circuit Plug in style terminal blocks for ease of service and mainte Fully supervised and power limited Diagnostic LEDs include yellow LED cable fault fault and green functional LED Provides interface to non fire paging equipment for non paging applications Provides plug in style terminal blocks for ease of service maintenance Transformer isolated 600 ohm audio connection to paging Electrically isolated contact closure trigger input for activa by the paging equipment Converts 25 Vrms audio outputs to 70.7 Vrms for retrofit Plugs directly on ACC AAM25 module s allowing indepen conversion to 70.7 Vrms Provides local digital message playback for user review of custom messages and Indicators INDICATORS Power On green System Trouble yellow Message Generator Trouble yellow Tone Generator Trouble yellow Microphone Trouble yellow Record Playback green All Call green Active Audio ON OFF green Active yellow Manual Deacti Status of each speaker zone green Active yellow Deactivation or Fault system LEDs Battery Trouble Charger Trouble Fault ACC AAM25 Speaker Circuit Trouble and Supervisory Line Information 25 watt 25 Vrms emergency Voice Evacuation Panel VECP with integral commercial microphone message generator zone splitter module ACC ZSM page module with keypad ACC ZPMK Optional 25 watt 25 Vrms Audio Amplifier Mod with single Class A or Class B speaker circuit Optional External Page Module Optional 70.7 Vrms Converter Module one per amplifier consult factory for availability Optional Remote Microphone includes backbox one VEC RM per system Optional Local Playback Speaker Series Two batteries required See FACP manual for current requirements see data sheet DN 6933 for of batteries Optional Remote Microphone includes backbox only FC RM per system Optional Trim Ring for semi flush mounting 2 of 4 DN 7003 A 1 14 10 1 14 10 Page 3 of 4 SPECIFICATIONS POWER AC 120 VAC 60 Hz 1.5 A Wire size minimum 14 AWG with 600 V insulation supervised Power Battery Charging Circuit Lead acid batteries only Maximum Charging Circuit Normal Float Charge 27.6V A Maximum Charger Capacity 18 Amp Hour battery NFV Series cabinet holds max 18 Amp Hour Battery Loss Relay TB7 Operation normally energized fail safe relay tr

Related Files