Notifier NFV-25 50ZST (FireVoice-25 50ZST) Zoned System Voice with Telephone Evacuation Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

NFV 25 50ZST System Voice with Telephone Control Panel FireVoice 25 50 Zone System with FireFighters Tele NFV 25 50ZST is a state of the art Emergency Voice panel EVAC panel capable of splitting 25 or 50 of audio power and up to eight speaker circuits i e The NFV 25 50ZST includes an NFV FFT Fire Fighter Module with keypad which provides indications of activation remote page activation remote microphone and corresponding trouble conditions Additionally to 24 telephone circuits can be annunciated at the NFV by connecting addressable monitor modules to the N FPJ or N RPJ Remote Phone Jacks The NFV 25 provides the ability to record five field programmable up to 60 seconds total message duration with an commercial grade emergency communications micro or from an external audio source Significant technolog enhancements set the NFV 25 50ZST apart from other panels these include full supervision in both active and standby conditions supervision of amplifier outputs wiring message generator all tone generators and the The integral power supply is capable of charging to 18 AH batteries which can be housed in the NFV 25 cabinet NFV 25 50ZST is suitable for use as an adjunct slave or to most UL Listed Fire Alarm Control Panels An optional 25 watt 25 VRMS audio amplifier is for system expansion to 50 watts or as a secondary in jurisdictions requiring such backup A 70.7 VRMS is also available for independently converting ampli to meet retrofit needs Zone Splitter Module ACC ZSM divides the output of the Amplifier Module s ACC AAM25 into up to eight circuits i e zones The Zone Page Module with Key NFV ZPMK provides full manual control of the speaker status indication of each of the speaker circuits and control by the FACP via the ACS serial link connec host of field programming options including the capability of custom messages fire tornado evacuation hazmat non multi language etc make the NFV 25 50ZST the most voice evacuation system available Suitable Applications Schools Restaurants Office Buildings Factories Theaters Dormitories Auditoriums Lodging Places of Worship Listed to UL Standard 864 9th edition 25 watts of audio power can be divided into eight Style Y B or four Style Z Class A speaker circuits zones the zone splitter module ACC ZSM Full manual control of all audio zones provided by zone module with keypad ACC ZPMK NFV FFT Fire Fighter Telephone module for control and of up to 24 remote telephone jacks Activation by the FACP using the ACS serial link and or the Command CMD inputs DN 60337 A C 22 Control Systems ACS serial link with compatible Notifier FACPs FACP auto directs the voice message to each or all audio Paging by zone or All Call Full status indication normal active fault of each speaker Fault indication via ACS serial link and or the two Form C relays System and AC Power Loss 25 watt 25 VRMS audio amplifier with single Style Class A or Style Y Class B speaker circuit expandable 50 watts using the ACC AAM25 Modular design for maximum system flexibility and ease of Two command input circuits can be independently field pro for activation by a Notification Appliance Circuit or contact closure Three command input circuits activate on contact closure ACS link or Command Input CMD control of One 60 second message Two 30 second messages Three 20 second messages Four 15 second messages Five 12 second messages Microphone time out feature Nineteen different system and diagnostic LEDs Optional equipment second amplifier playback remote microphone paging equipment interface remote phone jacks digital message generator with standard factory emergency evacuation message DN 60337 A 2 4 09 Page 1 of 6 Custom messages are field recordable without the addition costly add on modules utilizing the integral microphone the audio input jacks Digital message may be field selected for 3 4 6 8 or infi All outputs are power limited Auxiliary power output provides local power for addressable modules when used to activate the NFV 25 50ZST Compatible with specific Notifier FACPs as well as other repeat Built in alert tone generators with steady slow whoop high or chime tone capability Field selectable lead in trailing tone selection Alert tone selection may be field programmed to conform ANSI S3.41 Audible Emergency Evacuation Signal Pattern per NFPA Speaker zone control via ACS serial link CMD inputs or Dual optically isolated trigger input circuits are indepen field programmable for activation by polarity reversal FACP NAC or dry contact closure diagnostic LEDs include Power System Trouble Trouble Message Generator Trouble Tone Trouble Amplifier Fault and others ACS serial link or independent Form C trouble relay allows to monitor voice system while in active alarm state piezo provides local audible indication for troubles Fully supervised in Standby and Active states including microphone amplifier output message generator wiring and tone generators amplifier supervision current limit audio level circuit protection panels Modules 25 watt 25 VRMS Audio Amplifier Module with Class A or Class B speaker circuit Zone Page Module with keypad Zone Splitter Module These modules provide up eight speaker circuits that may be manually or automatically Fire Fighter Telephone Module with keypad which indications of phone activation remote page activa remote microphone activation and corresponding trouble Modules 25 watt 25 VRMS audio amplifier module Field programmable for system expansion to 50 watts or as backup to the primary 25 watt amplifier where required Provides single Class A or Class B speaker circuit Riser Circuit 1 Circuit 8 9 16 17 24 Control Serial Link RS 485 to 24 Control the ACS Link or Input The FACP controls the audio system via the ACS Link or CMD on the NFV 25 50ZST The Audio Riser connects the audio output of the NFV 25 to each of the NFV 25 50DAZS s to distribute alarm or audio The NFV 25 50ZST uses the Control Serial Link to control the of the alarm or paging audio Riser conductors must be installed in accordance with the sur from attack by fire requirements in National Fire Alarm NFPA 72 2 of 6 DN 60337 A 2 4 09 Command Center Zone System With FireFighter Telephone to 24 Zones 150W max Utilizes plug in style terminal blocks for ease of service and Fully supervised and power limited Diagnostic LEDs include yellow trouble LED cable fault fault and green amp functional LED Provides interface to non fire paging equipment for non paging applications Provides plug in style terminal blocks for ease of service Transformer isolated 600 ohm audio connection to paging maintenance Electrically isolated contact closure trigger input for activa by the paging equipment Converts 25 VRMS audio outputs to 70.7 VRMS for retrofit Plugs directly on ACC AAM25 module s allowing indepen conversion to 70.7 VRMS Remote Microphone includes backbox only one FC RM system

Related Files