Notifier NP-100(A) Series Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | notifier-np-100-a-series-data-sheet-9608247351.pdf |
---|---|
Type | |
Size | 640.93 KB |
Downloads |
Text Preview
NP 100 A Series Photoelectric NP 100 A NP 100T A and NP 100R A addressable plug in photoelectric detectors use a state of the art sensing chamber with communications to provide area protection and are used exclusively with NOTIFIER Series FireWarden 100 2 and FireWarden 50 Spartan NSP 25 Addressable Fire Alarm Control Panels The NP 100T A adds thermal sensors that will alarm a fixed temperature of 135 57 Since these detectors addressable they will help emergency personnel quickly a fire during its early stages potentially saving precious time while also reducing property damage Two LEDs on sensor light to provide a local visible sensor indication LED annunciator capability is available as an optional PN RA100Z A The NP 100R A is a remote test detector for use with DNR A DNRW duct smoke detec housings LOOP Two wire loop connection Unit uses base for wiring Addressable by device Rotary decimal addressing 01 99 with FireWarden 100 2 NSP 25 and 01 50 with FireWarden 50 Unique single source dual chamber design to respond and dependably to a broad range of fires communications and built in type identification Sleek low profile design Built in tamper resistant feature Removable cover and insect resistant screen for simple field Withstands air velocities up to 4,000 feet per minute 20 m without triggering a false alarm Factory preset at 1.5 nominal sensitivity for panel alarm level Visible LED when the unit is addressed communicat with the fire panel and latches on in alarm Sealed against back pressure Direct surface mounting or electrical box mounting Mounts to single gang box 3.5 8.89 cm or 4.0 10.16 cm box or 4.0 10.16 cm square electrical box using plaster ring included SYSTEM FEATURES Fully coated circuit boards and superior RF transient protec 94 V0 plastic flammability rating Low standby current A1 320 Devices in B210LP A Base Remote LED output connection PN RA100Z A photoelectric detectors in life safety applications to provide broad range of fire sensing capability especially where smol fires are anticipated Ionization detectors are often better photoelectric detectors at sensing fast flaming fires detectors are constructed of off white fire resistant plas NP 100 A series plug in low profile smoke detectors are to commercial standards and offer an attractive series plug in detectors use a detachable mounting to simplify installation service and maintenance base all base types on an electrical backbox which is at 1.5 3.81 cm deep For a chart of compatible junction see DN 60054 Because of the inherent supervision provided by the SLC end of line resistors are not required Wiring or are permitted for Style 4 Class B wiring NP 100R A in a DNR A DNRW duct detector housing NP 100 A series detector uses one of 99 possible on the FireWarden 100 2 and NSP 25 or one of 50 addresses on the FireWarden 50 Signaling Line Circuit It responds to regular polls from the system and reports type and status addressable photoelectric sensor in the NP 100 A series a unique unipolar chamber that responds quickly and uni to a broad range of smoke conditions It can withstand gusts up to 4,000 feet per minute 20 m sec without an alarm level signal Because of its unipolar chamber NP 100 A series is approximately two times more respon than most photoelectric sensors This makes it a more sta detector 2 11 2015 Page 1 of 2 BASES suffix indicates ULC Listed model For details about intelligent bases and their mounting see Plug in detector base included standard U S low profile mounting base Bulk pack of B210LP package contains 10 Standard European flangeless mounting base Bulk pack of B501 package contains 10 Intelligent sounder base capable of producing output with ANSI Temporal 3 or continuous tone B501BH series bases in retrofit applications Plug in System Sensor relay base Screw termi up to 14 AWG 2.0 mm Relay type Form C Rating 2.0 30 VDC resistive 0.3 A 110 VDC inductive 1.0 A 30 inductive Plug in System Sensor isolator detector base 25 devices between isolator bases see DN 6994 Retrofit flange to convert B210LP A to match the profile or to convert older high profile bases to low Bulk pack of F110 package contains 15 Replacement flange for B210LP A base Remote LED annunciator 3 32 VDC Mounts to a single gang electrical box For use with B501 A and bases only Surface mounting kit magnet Test magnet with telescoping handle Detector removal tool Allows installation and or removal detector heads from bases in high ceiling applications Extension pole for XR2B Comes in three 5 foot 1.524 m Detector removal tool without pole Black detector covers for use with NP 100 A only of 10 White detector covers for use with NP 100 A only of 10 Sensitivity Test detector can have its sensitivity tested required per NFPA Chapter 14 on Inspection Testing and Maintenance when to a FireWarden 100 2 or FireWarden 50 fire alarm control panel The results of the sensitiv test can be printed off the FireWarden 100 2 or FireWarden for record keeping range 15 32 VDC peak current 300 24 VDC current 6.5 mA 24 VDC latched velocity 4,000 ft min 20 m sec maximum 2.1 5.33 cm high base determines diameter B210LP A 6.1 15.5 cm diameter B501 A 4.1 10.4 cm diameter B200SR A 6.875 17.46 cm diameter B224RB A 6.2 15.748 cm diameter 3.6 oz 102 g temperature range for NP 100 A 0 to 49 to 120 for NP 100T A 0 to 38 32 to 100 installed in a DNR A DNRW 20 to 70 4 158 0 49 32 120 humidity 10 93 non condensing and approvals below apply to the NP 100 A NP and NP 100R A detectors In some cases certain may not be listed by certain approval agencies or list may be in process Consult factory for latest listing status UL Listed S1115 ULC Listed S1115 CSFM 7272 0028 0231 MEA 243 02 E Vol 2 Maryland State Fire Marshal permit 2173 FM approved Line Information suffix indicates ULC Listed model Addressable photoelectric detector B210LP base Sames as NP 100 with ULC Listing B210LPA base Same as NP 100 but with thermal element B210LP included Same as NP 100T with ULC Listing B210LPA base Remote test capable addressable photoelectric for use with a DNRA DNRW duct detector housing base included Same as NP 100R with ULC Listing for use with a duct detector housing B210LPA base included and FireWarden are registered trademarks of Honeywell Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Notifier Phone 203 484 7161 FAX 203 484 7118 2 of 2 DN 6995 D 2 11 2015