Notifier NSP-25(E) Rev 2 Spartan-25 Addressable FACP With Built-in Communicator

File Preview
File Preview
Click below to download for free

Text Preview

NSP 25 E Rev 2 Addressable FACP Built in Communicator NOTIFIER Spartan 25 NSP 25 NSP 25E is a 25 point Fire Alarm Control Panel FACP with built in Dig Alarm Communicator Transmitter DACT This control supports up to 25 addressable devices in any combina of detectors and modules With simple programming on standard wire and features such as drift compen and maintenance alert the Spartan 25 is a preferred to conventional control panels in both new and ret applications JumpStart or auto learn feature and easy to set code addressing of Honeywell Fire Systems HFS or equiva Notifier detectors and modules enable the system to be for fire protection without a programming utility The programming can be modified using the panels embed web server integral DACT transmits system status alarms troubles etc to a remote monitoring location via the switched telephone network Reporting formats are con ID SIA 8 or SIA 20 Unless otherwise specified the term Spartan 25 is in this data sheet to refer to the Spartan 25 and the Spar For details on the Canadian version see DN 60705 SBUS supports two ANN 80 Remote Annunciators JumpStart auto learn feature reduces installation time makes programming easy Built in digital communicator communicator compatible Two programmable Style Y Class B notification appliance NACs Selectable strobe synchronization for System Sensor Wheelock or AMSECO devices Two programmable Form C relays and one Form C trouble NFPA 72 Automatic detector sensitivity testing NFPA 72 compliant Point status eliminates calibrated smoke test requirements Drift compensation Alarm verification per zone of detectors Walk test Detectors and modules are code wheel addressed for installation time Maintenance alert region Uses standard wire unshielded or twisted pair Central Station reporting up to five zones Custom programming performed control built in browser no programming software is Fire Alarm Control Panels Communication Single addressable SLC loop which meets NFPA Style 4 B requirements 25 addressable device capacity any combination of detectors and modules Compatible with Honeywell Fire Systems HFS or equiva Notifier detectors and modules Appliance Circuits NACS Two independently programmable output circuits Circuits be configured for the following outputs Style Y Class B Door Holder Service cannot be used for notification Aux Power Source cannot be used for notification appli Silence Inhibit and Auto silence timer options Continuous or Temporal code Selectable strobe synchronization per NAC Up to 2.0 A total output power 1.0 A for auxiliary power and holder Each circuit can source up to the total system 2.0 A and Software Auto learn JumpStart feature for easy programming Custom programming can be performed through control installation time built in browser 9 19 2011 Page 1 of 4 Interface INDICATORS AC Power green Fire Alarm red Supervisory yellow Alarm Silenced yellow System Trouble yellow Disabled yellow Low Battery Fault yellow Ground Fault yellow Walk Test yellow CONTROLS Acknowledge Silence Drill System Reset lamp test Disable per zone Disable per NAC JumpStart Line Information 25 point addressable fire alarm control panel main circuit board chassis backbox and door Black VAC Same as NSP 25 but operates from 220 240 VAC Same as NSP 25 but listed for Canadian applica For details on the Canadian version see DN 60705 FIRE SYSTEMS DEVICES Honeywell Fire Systems addressable photoelectric detector Includes base Honeywell Fire Systems addressable photoelectric detector with thermal sensor Includes base Station or HFS D Duct Smoke Detector or HFS MM Module or HFS MR Module or HFS P or HFS T Sensor Strobes Horns and NACs 2 of 4 DN 60703 A1 9 19 2011 Honeywell Fire Systems addressable fixed tempera heat detector Includes base Honeywell Fire Systems addressable Mini Monitor for normally open contact devices Honeywell Fire Systems addressable relay module Honeywell Fire Systems addressable photoelectric smoke detector Includes detector EQUIVALENT DEVICES Addressable dual action manual pull station Addressable low profile photoelectric smoke detector Addressable low profile photoelectric smoke detec with thermal sensor Fast response low profile heat detector InnovairFlex low flow non relay duct detector housing NP 100R ordered separately Addressable remote test capable detector for use DNR duct smoke detector housing Miniature version of FMM 1 Excludes LED and D option Connects with wire pigtails May mount in backbox Addressable relay module containing two isolated of Form C contacts which operate as a DPDT switch This module isolates the SLC loop from short cir conditions ANNUNCIATORS Remote LCD annunciator mimics the informa displayed on the FACP LCD display Recommended wire is un shielded Basic model is red order W version for see DN 7114 Red surface mount backbox with angled White surface mount backbox with wedge Surface mount backbox for the NOT BG12LX plastic Optional trim ring for semi flush mounting the pull Battery backbox holds up to two 25 AH batteries and Battery box houses two 55 AH batteries Battery charger for lead acid batteries with a rating 25 to 75 AH Remote battery charging system for lead acid bat with a rating of 55 to 120 AH Requires additional NFS for mounting Series Batteries See DN 6933 City Box Transmitter Module DACT Phone Cord 2 required Monitoring Module to primary and secondary DACT telephone output for internet communications over customer provided eth connection Requires compatible Teldat Central Station Receiver Can use DHCP or IP See DN 60408 for more information Y adaptor option allows connection of both panel outputs to one IPDACT 2 2UD cable input External mounting enclosure consisting of mounting IPBRKT and screws When using the supplied phone enclosure must be mounted within 6 15.24 cm of the Red Requirements shielded wire is not required it is recommended that all wiring be twisted pair to minimize the effects of electrical Refer to the panel manual for wiring details 9 19 2011 Page 3 of 4 SPECIFICATIONS Capacity Signalling Line Circuits 1 Addressable device capacity 25 Programmable software zones 5 Annunciators 2 Specifications AC Power NSP 25 120 VAC 60 Hz 1.5 A NSP 25E 230 50 60 Hz 0.75 A AC wire size is minimum 14 AWG mm with 600 V insulation Nonpower limited super Battery Charging capacity 7 33 AH 18 AH for ULC appli NSP 25 cabinet holds maximum of two 7 AH bat Larger batteries require a separate battery cabinet as the BB 26 or NFS LBB Communication Loop Supervised and power limited Notification Appliance Circuits Terminal Strip

Related Files