Potter AFC-1000V Integrated Voice Emergency Evacuation Panel

File Preview
File Preview
Click below to download for free

Text Preview

Features single and dual channel applications programming to 2 hours of message storage to 255 customizable audio patterns message library of predefined messages and tones to record and import message files from a laptop up to 104 programmable push buttons for speaker and ECS push buttons for All Call supervised auxiliary input to interface with low level audio sources Music up to 10 SCA single channel or DCA dual channel amplifiers with LOC 1000 Local Operator Console to control the system remote areas Fire Fighters Telephone system features of the AFC 1000 included AFC 1000V is an enhanced version of the AFC 1000 addressable alarm system now with voice integration The panel features all pre fire highlights and shares new innovative voice functionalities provide reliability and safety with the panel The panel introduces VM 1000 voice module and digital message repeater to deliver to designated remote amplifiers The VM 1000 contains two channels audio riser outputs to support single and dual channel The voice module also includes a supervised low level auxiliary to interface with external audio sources and supports applications background music The AFC 1000V is equipped with an ECS interface providing 8 programmable push buttons for speaker and zone assignment LED indicators to display activity and trouble and common user function buttons for All Call and CTRL optional SB 24 Switch Board w 24 Programmable Switches will 24 additional programmable push buttons A maximum of four 4 can be installed offering up to 96 programmable push buttons AFC 1000V can link up to ten 10 SCA single channel amplifier DCA dual channel amplifier amplifiers thirty 30 LOC 1000 local console and one 1 FFT 1000 Firefighter Telephone System Potter Panel Programmer introduces Audio Patterns which allows to select and create audio files easily and effectively from the user The programmer offers an internal library of predefined message tones for common emergency conditions Audio Patterns provides the to conveniently record and import audio files directly from a laptop Mains Specifications 3 8 x 29 1 8 x 4 7 8 Amps 120 VAC 50 60 HZ Amps 240 VAC 50 60 HZ gauge cold rolled steel with removable locked door Lexan viewing window Current 130 mA Current 220 mA Amps power for NACs I O and P Link Amps per NAC regulated Amp per I O circuit regulated Battery Charger range 8 55 Ah Battery Charger voltage 27.3 VDC maximum current of 1 Amp to 120 0 to 49 with a maximum humidity of non condensing and Range PAGE 1 OF 3 Voice Fire Alarm Panel8830182 REV A 9 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Connection IPA 4000 is shipped standard with an Ethernet connection This is the programming port and may be connected to a building Area Network WAN or Local Area Network LAN Once to the Internet the panel may be selectively programmed e mail alarm conditions trouble conditions supervisory conditions Event History and detector status An e mail may be sent to the and the panel will e mail the event history detector status file or server status to an authorized E mail account In reminders may be set to send an e mail for service testing other conditions addition the Ethernet connection is UL listed as an IP communicator IP communicator is listed to report to the UL listed Sur Gard III receiver The IP communicator replaces the traditional less reliable communicator transmitter that utilized telephone lines The IP is an active method of connection and communication the monitoring station Accessory Switch bank with 24 programmable push buttons Maximum of 4 SB 24s Interface AFC 1000V panel incorporates a SB 8 user interface to display ECS system status The panel is shipped with the LEDs common push buttons include All Call Reset and Ctrl to Page Requested Controlled Controlled AFC 1000V has a proprietary communication protocol that through a RS 485 connection to field devices Up 64 devices may be connected to a single P Link connection The includes the communication terminals and regulated 24 VDC for the field devices The field devices may be any of the Single channel 25W 25V amplifier Single Channel 25W 25V or 70V selectable amplifier Single channel 50W 25V amplifier Single Channel 50W 25V or 70V selectable amplifier Single Channel 100W 25V or 70V selectable amplifier Dual channel 50W 25V amplifier Dual channel 100W 25V amplifier Local operator console Fire fighter telephone system Firefighter Telephone System Right Hinge Door Firefighter Telephone System Left Hinge Door PAGE 2 OF 3 REV A 9 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comAFC 1000VIntegrated Voice Fire Alarm Panelfirealarmresources com 20 1 8 21 3 8 4 7 8 4 1 4 28 29 1 8 Information Voice Fire Alarm Panel No PAGE 3 OF 3 REV A 9 21Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comAFC 1000VIntegrated Voice Fire Alarm Panelfirealarmresources com

Related Files