Potter CS-24-WP Series Outdoor Colored Lens Strobe

File Preview
File Preview
Click below to download for free

File Data

Name potter-cs-24-wp-series-outdoor-colored-lens-strobe-8392476105.pdf
Type PDF
Size 1.68 MB
Downloads

Text Preview

Features Fixed 75cd strobe Available in surface mount standard and Low Profile LP WPBB LP made of clear Lexan provides maximum visibility reliability allowing full 75cd output Lens colors available in amber blue green and red Super Slide Bracket Ease of supervision testing Checkmate Instant voltage verification Synchronize strobe and or horn with AVSM module Switch selection for high low dBA Switch for chime whoop mechanical and 2400Hz tone Input terminals accept 18 to 12 AWG Switch for continuous or temporal 3 tone not available on whoop Tamperproof re entrant grill 5 year warranty CS CHS WP Series Outdoor Colored Lens Signals are wall low profile strobes and horn strobes that offer dependable and visual alarms for warning and emergency notification in locations Applications include emergency communication weather emergency response and many more CS CHS WP Series Outdoor Colored Lens Signals are 24VDC available in lens colors of amber blue green and red The Series a fixed 75 candela strobe They have a minimal operating current a minimum flash rate of 1Hz regardless of input voltage The enclosure is made of clear Lexan which provides visibility and reliability for effective visible signaling full 75cd output The strobes can be synced using a Gentex protocol or the AVSM Sync Module Colored Lens Series is shipped with a die cast universal 4 bracket which incorporates the popular Super Slide that allows the installer to easily pre wire the system and test supervision The product also features a locking mechanism that the signal to the bracket without showing any screws The Lens Series also features the Checkmate Instant Voltage Feature which allows the installer to check the voltage current draw and match against the blue print Version CS CHS WP Series devices are available in two different versions standard version comes with a surface mount back box WPBB install directly on a wall The Low Profile LP versions come with low profile back box WPLPBB designed to be installed on a flush electrical box Listings ANSI UL 464 and 1638 7135 0328 0212 CHS WP Series 7135 0328 0213 CS WP Series Specifications Voltage 24VDC 16 33VDC 150 35 66 Version 5.75 H x 4.75 W x 3.25 D 5.75 H x 4.75 W x 4.18 Connections accept 18 12 AWG Weight Version Single gang double gang or square back box Version Surface mount back box lbs PAGE 1 OF 4 SeriesOutdoor Colored Lens Strobes and Horn Strobes8830058 REV B 1 15Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 1211 Customer Service 866 572 3005 www pottersignal comfirealarmresources com Series Outdoor Colored Lens Strobe 75 Candela Number Color Models with LP include the LP version enclosure Number Models with LP include the LP version enclosure Max Strobe Current Ratings 24VDC Regulated Green and Lens Lens unfiltered FWR ratings see installation manual Decibel and Current Ratings at 10 UL 464 at 10 UL 464 24VDC Operating at High mA Setting 3 2400Hz 3 Mechanical 3 Chime 2400Hz Mechanical Chime the horn in this mode at this voltage will result in not meeting minimum ANSI UL 464 reverberant sound level required for public fire protection service These settings are acceptable only for mode fire alarm use Use the high dBA setting for public mode not applicable when using the chime tone The chime tone always private mode PAGE 2 OF 4 Series Colored Lens Strobe 75 Candela Color dBA at 10 per ANSI UL 464 Anechoic Room dBA at 10 8830058 REV B 1 15Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 1211 Customer Service 866 572 3005 www pottersignal comCS CHS WP SeriesOutdoor Colored Lens Strobes and Horn Strobesfirealarmresources com Switch Locations Temporal 3 Continuous Temporal 3 Continuous Temporal 3 Continuous Position Positions 1 and 2 in the OFF position to select horn and strobe power inputs Position 6 ON HIGH dBA Position 6 OFF LOW dBA Slide Mounting Bracket the installer to pre wire the system test for system remove the signal head until occupancy switch signals without changing mounting brackets and has edge connector for snap in place installation Outdoor Enclosure Slide Mounting Plate to WPBB Outdoor Enclosure Slide Mounting Plate to WLPBB Outdoor Enclosure Instant Voltage is often necessary to confirm the voltage along the line of devices The access are provided in the back of the block to allow the voltage to measured directly without removing device Typically this would be done the end of the line to confirm design Most measurements will be taken the S and S locations although is provided to other locations Care should be taken to not the test probes PAGE 3 OF 4 SeriesOutdoor Colored Lens Strobes and Horn Strobes8830058 REV B 1 15Potter Electric Signal Company LLC St Louis MO Tech Support 866 956 1211 Customer Service 866 572 3005 www pottersignal comfirealarmresources com Diagrams All strobes are designed to flash as specified with continuous applied voltage Strobes should not be used on coded or pulsing signaling circuits use of the AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe horn and or mute the horn SYNCHRONIZATION WIRING INFORMATION REFERENCE AVSM CONTROL MODULE DATA SHEET 8830050 AND OR CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS AVSM CONTROL MODULE SHEET AND MANUAL CAN BE OBTAINED AT http pottersignal com OR CALL POTTER ELECTRIC AT 1 800 325 3936 and Engineering Specifications audible and or visible signal shall be Potter Outdoor Colored Lens Commander Series or approved equal and shall be listed by Underwriters Inc per ANSI UL 1638 and or ANSI UL 464 The notification appliance shall also be listed with the California State Fire Marshal CSFM notification a

Related Files