Potter EFT-C Coded Electric Fire Alarm Transmitter
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-eft-c-coded-electric-fire-alarm-transmitter-0475169823.pdf |
---|---|
Type | |
Size | 1.32 MB |
Downloads |
Text Preview
EFT C ELECTRIC FIRE ALARM Listed and FM Approved 12 5 16 H x 8 5 16 W x 3 5 8 D H x 21,1cm W x 9,2cm D 9 lbs 4,05 kg 18GA CRS Finish Red enamel ferrous metal parts painted or the equivalent to resist Ratings Relay 3 Amps 250V AC or 30VDC Trouble Relay 3 Amps 250V AC 30VDC Ratings Contacts Limited Energy at 150V DC Input 12V AC 10VA Min Listed Class II Requirements 6V 1.0AH 60 second retard for waterflow alarm devices Trouble Relay Stock No 5190147 Model ULT Stock No 1000391 if by authority having Model EFT C is an electric motor driven for use on McCulloh type signal adjustment on the circuit board provides motor speed adjustment from 1 to 4 pulses per second transmitter provides a Class A supervised circuit for connection of NORMALLY devices such as heat sensor thermo smoke and ionization detectors alarm switches and manual pull sta The EFT C utilizes an external low voltage transformer A built in battery charger the battery which provides in excess 72 hours of standby operation A low battery circuit insures battery integrity SPDT alarm contacts are provided and an plug in relay is available to provide trouble contacts An electronic retard approximately 60 seconds delay on alarm transmission if desired see 1 Fig 2 One round trouble signal indicates low battery or open detection circuit condition indicated by yellow LED on board reset switch to restore from trouble to normal when cause of trouble con has been corrected Four round alarm signal when Class A circuit is shorted by detection device round alarm signal from trouble condi Alarm condition indicated by red LED One round restore signal from to normal is automatic when short is from Class A detection circuit Electric Signal Company cid 127 2081 Craig Road St Louis MO 63146 4161 cid 127 Phone 800 325 3936 Canada 888 882 1833 cid 127 www pottersignal com IN USA 5400748 REV H cid 127 MKT 8860002 cid 127 9 01 1 OF 4 ELECTRIC FIRE ALARM Connect detector loop Activate reset switch Transmitter will run to condition Red and yellow LED off If transmitter will not run to the NORMAL check for open or grounded detec loop Check for low battery battery must at least 6 volts If transmitter runs and stops in ALARM condi red LED on check for short circuit detector loops Connect central office line earth ground and per Fig 2 1 CODE WHEEL REMOVAL AND CODING Mount EFT C Coding the Transmitter Code wheel must be removed code and code wheel and bracket reinstalled any power is applied to the transmitter Remove code wheel and metal bracket under wheel Cut code wheel to desired code Place hole in bracket over emblem on of code wheel recessed area see 1 Reinstall code wheel and bracket The tab must be centered in the slot in opto device on the circuit board see 2 Hold code wheel and bracket in this position tighten mounting nut Pull tamper switch plunger to deactivate tamper Connect POSITIVE red battery lead to terminal Connect NEGATIVE black battery lead to ter 22 The transmitter will run and stop in condition Yellow LED on Connect 12V AC from plug in transformer to 7 and 8 Activate tamper Transmitter will transmit one trouble signal Yellow LED will come on TROUBLE condition Activate a detector in the Class A detection The transmitter will transmit a three alarm signal Red LED will come on ALARM condition Pull tamper switch plunger to deactivate NORMAL condition Activate a detector in the Class A detection The transmitter will transmit a 4 round signal Red LED will come on indicating condition Restore detector in the Class A detection cir The transmitter will transmit a 1 round signal Red and yellow LED both out NORMAL condition Restore detector in the Class A detection cir The transmitter will transmit one round signal Red and yellow LED both out Verify that the central office receives clear and signals and that alarm and trouble devices are functioning properly INFORMATION NO Electric Fire Transmitter and Transformer not Less Housing P C only 6V 1.0AH IN USA NO 12V 20VA Relay 12V 15VA Listed Class II when required by authority jurisdiction 5400748 cid 127 REV H cid 127 MKT 8860002 cid 127 9 01 2 OF 4 ELECTRIC FIRE ALARM ELECTRIC FIRE ALARM TRANSMITTER INSTALLATION Code wheel must be removed code cut and code wheel and bracket reinstalled before power is applied to transmitter 2 CIRCUITS POWERED BY THIS CONTROL ARE LIMITED Add jumper to obtain approximate 60 second delay when EFT C is used to supervise wet system Supervised Loops Limited Energy Loop Resistance 200 Ohms per loop Ohms total both loops N O initiating devices such as Thermostats Manual Station Waterflow Switches etc Class 2 transformer rated 12V 10VA systems requiring a metal enclosed wiring system use Model ULT Stock No 1000391 Battery Design life is 4 years Mark date on battery and charge for 48 hours before placing unit service Tamper Closed with cover in place For additional installation and operating procedures see pages 1 and 2 of this bulletin Use National Fire Alarm Code NFPA 72 Central Station Proprietary Remote Station Protected Premise Unit IN USA 5400748 cid 127 REV H cid 127 MKT 8860002 cid 127 9 01 3 OF 4 3 WIRING INSTRUCTIONS ELECTRIC FIRE ALARM EFT C contains Limited fire protec signaling circuit conductors and Class 1 elec Limited circuit conductors control unit enclosure provides multiple cable openings so that the Limited fire signaling conductors can be segre from the Class 1 electric Lim conductors cable entry opening in the top should used for the Class 1 Limited as the power inputs are located in this two bottom enclosure cable entries must be for the Limited fire protective signal conductors specific wiring routing see Fig 4 4 ROUTING must be installed from back side of terminal block Battery wire terminals 21 and 22 have spaghetti from terminal to hole in P C board Cover tamper wires are covered with spaghetti and run from terminals 1 and 2 under P C board the lower right hand standoff to the tamper switch this is factory installed wiring Wires from terminals 3 through 12 exit through lower left hand side knockout Wires from terminals 15 through 20 exit through the top center knockout IN USA 5400748 cid 127 REV H cid 127 MKT 8860002 cid 127 9 01 4 OF 4