Potter PFC-100RC Releasing Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name potter-pfc-100rc-releasing-control-panel-1370856492.pdf
Type PDF
Size 593.90 KB
Downloads

Text Preview

PFC 100RC RELEASING CONTROL PANEL One Initiating Device Circuit Selectable Class A or Class B One Class B Circuit for dry contact devices One 500mA Class B Indicating Circuit One 1 Amp Class B Releasing Circuit One Class B Supervisory Circuit 2 Amps Alarm and Trouble Contacts 200mA Auxiliary Power Output Supervised Integral Battery Charger Supports 2 or 4 Wire Detectors Field Selectable Pre Discharge and Releasing Circuit Times 18 1 4 X 14 1 4 X 4 3 4 Description PFC 100RC is a full featured single hazard releasing control for use on pre action and deluge type sprinkler systems The PFC 100RC is Underwriters Laboratories Listed and complies UL Standard 864 for Local Control Units for Releasing Service is designed to be compatible with the requirements of NFPA 72 NFPA 12A NFPA 12B NFPA 13 and NFPA 17 The is FM NYMEA and CSFM Approved PFC 100RC features LED indicators for AC ALARM SILENCE and SUPERVISORY conditions that are with the door closed Operator controls are provided for SILENCE and RELEASE CIRCUIT DISABLE Thirteen board LED indicators provide extensive diagnostic ability to ease Alarm and trouble relays are provided to interface auxiliary equipment PFC 100RC is housed in a steel cabinet with removable door key lock Standard nish is off white with grey and red trim Red with black and white trim are also available A matching is available as an option for semi ush mounting in a wall The will house up to a 12AH standby battery which is capable of the unit in excess of 90 hours Information No Control White Cabinet Control Red Cabinet for Semi Flush Mounting White for Semi Flush Mounting Red 12V 4.0AH for 24 Hr Standby 2 req 12V 8.0AH for 60 Hr Standby 2 req 12V 12.0AH for 90 Hr Standby 2 req No Electric Signal Company 2081 Craig Road St Louis MO 63146 4161 Phone 800 325 3936 Canada 888 882 1833 www pottersignal com IN USA 8900087 REV J 1 OF 2 Speci cations control panel for the extinguishing agent releasing system shall of the single hazard type It shall be Underwriters Laboratory under Standard 864 for Local Control Units for Releasing The control shall also be approved by Factory Mutual Corporation and be compatible with the requirements of Local A M SS service types NC signaling type NFPA NFPA 12A NFPA 12B NFPA 13 and NFPA 17 control shall be housed in an 18 gauge steel cabinet that has a removable door with a key lock The nish shall be baked and available in red or off white with contrasting trim and An optional matching trim bezel should be available for semi ush mounting The cabinet shall have adequate space to house batteries capable of operating the system for up to 90 hours control shall include a fully supervised integral power supply charger capable of providing 200mA to auxiliary power 500mA to noti cation appliance circuits and 1 Amp to circuit The auxiliary power circuit shall be con gured provide switched and unswitched power circuits for powering devices simultaneously with 4 wire type initiating devices control shall have one single fully supervised initiating circuit of supporting the operation of 25 compatible smoke detectors zone shall be eld selectable to operate in the Class B Style or Class A Style D mode There should be a minimum of ve manufacturers with 2 wire smoke detectors compatibility for the control This circuit shall have a eld selectable pre time of 5 seconds or 45 seconds control shall have one fully supervised Class B Style B circuit for connection to pull stations or approved N O contacts for the purpose of initiating a release The circuit shall the pre discharge time setting of any other initiating circuit cause an immediate actuation of the release circuit control shall have one fully supervised Class B Style B circuit for connection to valve tamper or pressure RELEASING CONTROL PANEL switches as required Operation of this circuit shall result a distinct supervisory indication control shall have one fully supervised Class B Style Y cation appliance circuit The circuit shall require the use of noti cation appliances control shall have one Class B Style Y releasing circuit that be fully supervised for open and short circuits as well as foreign The releasing circuit shall polarity reverse when a releasing occurs The circuit should be compatibility listed with from at least three manufacturers The releasing circuit shall a eld selectable operating time of 90 seconds or continuous following LED shall be visible with the door closed AC ALARM Red TROUBLE Yellow SUPERVISORY The following diagnostic LED shall be visible with the open Low or Missing Battery Voltage Supervisory Cross Aux Fail 4 Wire Power Fail Ground Fault Releasing Circuit Current High Resistance in Supervised Circuit Noti cation Circuit Over Current Initiating Circuit High Resistance following switches shall be accessible when the cabinet door is RESET instantaneously resets all alarm circuits if the condition been corrected and momentarily removes power to initiating circuit 4 Wire detector power circuit SILENCE restores all noti cation and internal buzzer to normal RELEASING CIRCUIT prevents operation of releasing circuit control shall have one Form C SPDT alarm contact and one A SPST trouble contact each rated at 2 Amps The operation the trouble contact shall be eld selectable to follow the trouble operation or follow trouble conditions The operation of local buzzer can be eld selectable to operate during an alarm in addition to operating in a trouble condition IN USA 8900087 REV J 2 OF 2

Related Files