Potter PFC-3005T Conventional 5 Zone Fire Panel

File Preview
File Preview
Click below to download for free

File Data

Name potter-pfc-3005t-conventional-5-zone-fire-panel-6485732091.pdf
Type PDF
Size 655.89 KB
Downloads

Text Preview

FIVE ZONE FIRE ALARM PANEL Five Class initiating circuits Two Class indicating circuit Individual Zone Silence Disconnect switches Powerful 3mA capacity per zone for 2 wire Common alarm Relay contact Form C 28 VDC 3 AMP detectors Selectable common trouble contact 28 VDC 3 Amp Resistive A C ON LED Green Zone Alarm LED Red Signal Trouble LED Amber Remote Lamp Fail LED Amber Ground Fault LED Amber Battery Fault LED Amber Alarm Silenced LED Amber Common Trouble LED Silence switch Remote Trouble Indicator output Remote A C On output Selectable 1 minute Signal silence inhibit Extensive Transient Protection on all circuits Exterior color Red or Beige Annunciator Outputs available All circuits are power limited Stock No 3002006 Stock No 3002007 for additional listings PFC 3005T panel is designed for non coded re alarm in small commercial institutional and industrial A slim line design and a neutral beige exterior color an unobtrusive appearance to complement any interior PFC 3005T includes one circuit board providing all the for a complete re alarm system Five Class circuits and two Class B indicating circuits are provided the PFC 3005T The indicating circuit is protected from shorts self restoring circuitry includes ground fault detection battery low level open wire fault initiating and indicating circuit wiring faults loss of A C power Initiating circuits are supervised for and ground faults Indicating circuits are supervised for shorts and ground faults LED indicators are provided Zone Alarm Zone Trouble A C On Battery Fault Ground Common Trouble Signal Trouble and Signal Silenced are provided for Zone disconnect silence trouble and reset a trouble condition the trouble LED will ash and the audible signal will pulse Activating the switch silences the trouble signal and the remains ashing the trouble condition clears the common trouble LED to normal and the common trouble buzzer resounds until the Trouble Signal silence switch is returned to The alarm signals cannot be silenced for one minute if the minute inhibit feature has been selected jumper selectable PFC 3005T has selectable audible tones which can be gured via DIP switches for Steady and Temporal Code common alarm relay can follow the signal circuit or lock on the alarm has been reset This option is jumper selectable outputs are provided for alarm remote trouble and buzzer Lamp supervision is jumper selectable PFC 3005T controls are behind a durable locked door The will accommodate a 4 or 8AH battery pack Electric Signal Company 2081 Craig Road St Louis MO 63146 4161 Phone 800 325 3936 www pottersignal com IN U S A 1 OF 2 8900121 REV A ZONE FIRE ALARM PANEL AND INDICATING WIRING INSTRUCTION AND TROUBLE RELAY CONTACTS AND REMOTE WIRING INSTRUCTION Speci cations Circuits Voltage Limited Current Resistance of Line Resistor Circuits Voltage Current of Line Resistor Contacts Information No IN U S A VDC ltered and regulated mA mA up to 30 2 wire smoke detectors 100 uA each ohms max 5 1 2W VDC Total Current 1.7 ea x 2 5 1 2W VDC 3A Resistive x 12.7 322mm H x 2.8 71 mm D Zone Fire Alarm Panel Beige cabinet Zone Fire Alarm Panel Red cabinet Trouble indicator mounts onto a single gang electrical box Mounting Trim Ring 4.0 AH Battery 2 Required 8900121 REV A 2 OF 2

Related Files