Potter PFC-4064 Conventional Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

File Data

Name potter-pfc-4064-conventional-fire-alarm-control-panel-9718543620.pdf
Type PDF
Size 1.06 MB
Downloads

Text Preview

Features 6 programmable Initiating Device Circuits System is expandable to 192 input circuits using the IDC 6 module 5.0 amp power Supply 4 Strobe Synchronization for gentex aMSeCO System Sensor Cooper Wheelock One programmable auxiliary output rated at 1.0 a 4 x 20 LCD display with system LeDs for clear system status P Link Built in ethernet Connection with listed Ip Communicator Ability Service Reminder e mails pFC 4064 Conventional Fire panel is a compact expandable panel status to a monitoring station The pFC 4064 panel is a listed and UL 864 NFpa 70 and NFpa 72 The panel is provided with provides ample power to meet any jurisdictions requirements has the potter p Link for connection to system accessories panel also has a 1.0 amp auxiliary power output for controlling control panel is in a metal cabinet with a key lock and lexan for viewing the system status The printed circuit assembly is for quick removal and installation to allow the cabinet to be system status is clearly displayed and the panel includes a history for past events The key pad allows navigation into the system limited programming and system control The condition and on the panel are clearly displayed to allow the user and installer determine the system status Specifications gauge cold rolled steel with removable locked with Lexan viewing window amp 120 VaC 60 Hz amp 240 VaC 50 Hz ma Standby Mains Humidity 70 72 page 1 OF 5 Fire Alarm Control Panel8830139 REV E 9 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comfirealarmresources com Smoke Detector Compatibility Model Model SENSOR Brk Max No Of Detectors Per Zone Is 20 SYSTEM Max No Of Detectors Per Zone Is 25 Max No Of Detectors Per Zone Is 25 Max No Of Detectors Per Zone Is 25 page 2 OF 5 REV E 9 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPFC 4064Conventional Fire Alarm Control Panelfirealarmresources com Model Model Max No Of Detectors Per Zone Is 25 of the above Fenwal detectors and bases can be used in any combination Max No Of Detectors Per Zone Is 25 If using a mix of System Sensor and other smoke detectors a maximum of 20 detectors shall be permitted REV E 9 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPFC 4064Conventional Fire Alarm Control Panelfirealarmresources com Interface to the system status The keypad has navigation keys allow manipulation of the Menu on board the panel The panel is standard with the following LeDs aC power green alarm Red common buttons include a Silence Reset acknowledge and all of the buttons are accessible once the locked door is Fault amber amber amber amber pFC 4064 has a proprietary communication protocol that includes the communication terminals and regulated 24 VDC Initiating device circuit expander provides an additional six 2 x 16 LCD annunciator with a key pad in a locked enclosure 4 x 40 LCD annunciator with a key pad in a locked enclosure Flush mount version available 16 LeD annunciator with common indicators in a metal enclosure Flush mount version available 10 amp remote intelligent power supply with 6 2 Inputs and a p Link repeater Class a convertor that converts the NaCs and p Link UL listed Dual line telephone alarm communicator LeD driver expander used to connect up to 50 LeDs in a display Fire communication bridge provides remote mounting the ethernet connection Fiber interface module used to extend p Link to multi 24VDC 125aC Serial parallel gateway allows for the connection to a or parallel printer FIB 1000 FCB 1000 and the SPG 1000 may be installed in the bracket or ordered with the optional rack mount enclosure Multi Connect allows up to sixty three panels to share a reporting technology Two card expansion cabinet eight card expansion cabinet Fourteen card expansion cabinet Connection pFC 4064 is shipped standard with an ethernet connection connection is the programming port and may be connected to e mail alarm conditions trouble conditions conditions test event History and detector status an may be sent to the panel and the panel will e mail the event e mail account In addition reminders may be set to send e mail for service testing or other conditions addition the ethernet connection is UL listed as an Ip The Ip communicator is listed to report to the UL Sur gard III Ip receiver The Ip communicator replaces the less reliable alarm communicator transmitter that utilized lines The Ip communicator is an active method of and communication to the monitoring station page 4 OF 5 REV E 9 19Potter Electric Signal Company LLC St Louis MO Phone 800 325 3936 www pottersignal comPFC 4064Conventional Fire Alarm Control Panelfirealarmresources com SIDE SIDE Information Fire alarm Control panel Board No page 5

Related Files