Potter PFC-5004E Microprocessor-Based 4 Zone Expandable Fire Alarm Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | potter-pfc-5004e-microprocessor-based-4-zone-expandable-fire-alarm-control-panel-6013492785.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
PFC 5004E ALARM CONTROL PANEL 4 Class B Style B with 2 Class A Style D Initiating Circuits up to 8 Class B Style B 4 Class A Style D Circuits Predefined Initiating Circuits can be configured as Waterflow or Latching Supervisory Selectable Alarm Verification on Initiating Circuits Zone Disconnect Switches 5 Amp Power Supply 2 Class A B Style Z Y Notification Circuits 1.7 Amps max per Expandable up to 4 Class A B Style Z Y Notification Each Notification Circuit can be configured as Silenceable or Audibles may be configured as Steady Temporal Code California or March Time Auto Signal Silence Auxiliary relay contacts for Common Alarm Common Trouble Common Supervisory Built in RS 485 Interface for RA8F Multiplexed Remote Up to 3 Annunciators Built in Walk Test operation Output for 4 wire resettable regulated smoke power supply Easy configuration via DIP switches Specs Mains 2.0 Amps 120 VAC 60HZ 1.0 Amps 240 VAC 50 HZ The indicating circuits may be configured as Silenceable or with the audibles configured for Steady March Time Code or California Code Sync module required for strobe PFC 5004E is equipped with auxiliary relay contacts for Common Trouble and Supervisory If no Supervisory circuits are enabled Supervisory relay becomes a second Alarm relay The cabinet is in a beige color for the Canadian market and a red exterior for U S and International markets 110 mA Standby 220 mA Alarm Capability 4 24 AH Batteries is provided for up to 12 AH batteries 7 8 H x 14 1 2 W x 5 D No 3992020 0155 Modules UDACT 9100 Digital Communicator ZA 42 Zone Adder Module ARM 4 Quad Relay Module includes a 5 year warranty PFC 5004E Fire Alarm Control Panel is a microprocessor unit designed for small to medium commercial residential multi institutional and industrial occupancies Fully configurable DIP switches it enables the user to configure the system to meet specific requirements PFC 5004E comes standard with 4 Class B Style B Initiating which may be configured as 2 Class A Style D circuits In it comes equipped with 2 Class A B Style Z Y Indicating which are each rated at 1.7 amps The PFC 5004E can be up to 8 Class B Style B or 4 Class A Style D Initiating and 4 Class A B Style Z Y Indicating circuits with the addition a ZA 42 Adder Circuit Module The panel also INCLUDES A 5 Amp Supply which powers the system and supplies a 4 wire resettable smoke power supply of 24 VDC 100mA maximum PFC 5004E utilizes a simple DIP switch configuration for initiating and indicating circuits as well as the enabling disabling of system functions such as Signal Silence Fire Drill and Disconnect Some predefined initiating circuits can optionally configured Waterflow or Latching Non Latching Supervisory In the PFC 5004E allows for Alarm Verification on the initiating Electric Signal Co LLC St Louis MO Cust Service 866 240 1870 Tech Support 866 956 1211 Canada 888 882 1833 www pottersignal com 1 OF 2 IN U S A MFG 8900104 REV I06 12firealarmresources com Information No No Modules ZA 42 Annunciator RA8F ALARM CONTROL PANEL expandable to Eight Zone Microprocessor Based Fire Alarm Control Panel c w Class B Style B or 2 Class A Style D Initiating Circuits 2 Class A B Style Z Y Circuits and a 5 Amp Power Supply Expandable up to 8 Class B Style B Circuits or 4 Class A Style D and 4 Class A B Style Z Y Indicating Circuits for one UDACT 9100 Communicator or one PR 5000 Priority Reversal Module Class B Style B or Two Class A Style D Initiating Circuit and 2 Class A B Z Y Indicating Circuit Module Alarm Communication Transmitter Dialer Module Requires CFG LCD for UDACT Relay Module c w 4 configurable relays Multiplex Annunciator c w Common Control Features Indicators and 8 LEDs Signal Silence Buzzer Silence Lamp Test System Reset A C On Common Trouble Signal Silence Volt 4 Amp Hr Battery 2 pcs required per panel Volt 8 Amp Hr Battery 2 pcs required per panel Volt 12 Amp Hr Battery 2 pcs required per panel 2 OF 2 8900104 REV I06 12PRINTED IN U S A firealarmresources com