Potter PFC-6075 75 Point Addressable Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Features Analog Addressable Points in Any Combination Amp Power Supply NACS 2 Regulated Rated at 3 Amps each 2 Input Output Circuits rated at 1 Amp each Synchronization and System Wide Sync for Potter Gentex Cooper Wheelock and System Sensor Software Zones LCD and Keypad for Ease of Operation with enclosure rather than cabinet will house 8 or 18 AH Dead Front Cabinet for Clean Look Detector Drift Compensation and Maintenance Alerts wide Class A or Class B Event History Buffer NFPA 72 Compliant Smoke Sensitivity Test Built In Optional two line DACT UD 1000 Specs AC Mains Communication Line for Annunciators and Accessories Port for Programming and Network Connectivity System Status Reports and Event Information Listed IP Communicator W x H x D 16 x 17 x 3 7 8 Amps 120 VAC 50 60 H2 Amps 240 VAC 50 60 H2 mA Standby Alarm Fire Dept of Approval includes a 5 year warranty PFC 6075 is a versatile seventy five 75 point analog addressable fire alarm control panel that utilizes the Potter Nohmi device protocol has a complete line of initiating and control devices The SLC is capable of 50 ohms of resistance and does not require the use of twisted or wire The signaling line circuit may be any combination of smoke sensors heat detectors or modules PFC 6075 has a metal cabinet with a key lock and a dead front standard The cabinet will house 8 Ah or 18 Ah batteries The large viewing allows easy viewing of the LCD and the standard LEDs The keypad allows easy operation and navigation of the system menu panel has a 5 amp power supply with two 2 notification circuits each rated at 3 amps and two 2 Input Output I O circuits each rated at amp All of the outputs are power limited power regulated and may be programmed for Potter AMSECO Gentex CooperWheelock and Sensor strobe synchronization The outputs may be configured for any combination of strobe brands and all will sync The outputs also be configured for door holder power auxiliary power and constant power panel has auto programming learn mode that will not affect the existing system when adding or deleting a device The system is capable 99 software zones cross zoning and counting zones The panel is fully programmed from a PC based software program that will work with XP Vista or Windows 7.0 operating systems PFC 6075 has an Ethernet connection for programming network connectivity and IP reporting communicator The system uses a simple cable for connecting a PC to the panel In addition the system may be connected to a building network and programmed while on the The system has a built in e mail function and will send system E mail reminders The IP communicator is listed with the Sur Gard III receiver panel will support P Link devices which include the RA 6075 RA 6500 and LED 16 Annunciators RLY 5 Relay Module SPG 1000 Se Parallel Gateway printer card FCB 1000 Remote Ethernet IP connection only 1 DRV 50 LED driver for 50 LEDs PSN 1000 Remote Supplies 10 Amp and FIB 1000 P Link Fiber Interface Module In addition the panel allows for the installation of the UD 1000 dual telephone line digital alarm communicator transmitter DACT The UD 1000 is programmable for a single line or dual line and is compat with Ademco Contact ID or SIA DCS protocols The UDACT will report general zone or point complete system may be converted to Class A with a CA 6075 module The CA 6075 provides the hardware necessary to convert the re annunciators through the Potter P Link connection protocol the NACs and the SLC to Class A operation Electric Signal Company LLC St Louis MO Cust Service 866 956 1211 Tech Support 866 240 1870 Canada 888 882 1833 www pottersignal com 1 OF 3 8830001 REV C11 13PRINTED IN USAPFC 6075FIRE ALARM CONTROL PANELfirealarmresources com Loop Accessories control panel may be connected with up to seventy five 75 addressable devices or modules in any combination The SLC is not restricted any special wire requirements and may be wired with any wire that complies with the NEC Loop Devices Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot Analog Photo Electric Smoke Heat Detector a smoke detector with a listed obscuration of 1.02 to percent obscuration and a fixed temperature 135 Fahrenheit heat detector Fixed Temperature Heat Detector that is selectable from 135 F to 185 Rate or Rise Heat Detector that has a fixed temperature selection from 135 and 174 and also will if the temperature increase 12 15 in one minute Duct Smoke Detector round base that is mounted to an electrical box and wired for connection of one of the above sensors round base that is mounted to an electrical box and wired for connection of one of the above sensors base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Relay Base that contains two relays controlled by the SLC One relay is rated at 8 amps at 240 and the other is rated at 2 amps 240 VAC 30 VDC Sounder Base that contains an addressable sounder module that may be configured for local group all call The sounder follows the pattern sent to the device Contact Module provides a small foot print contact module for mounting inside an enclosure Action Addressable Pull Station Action Addressable Pull Station Contact Module is a standard contact module with an LED that mounts into a 4 square electrical box Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode Relay Module provides two form C relays that simultaneously active when the module is triggered by the panel Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC Output Module switches monitored power and is activated by the control panel Input Zone Module is used to connect conventional smoke detectors Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the Devices remote annunciator with a metal enclosure and key lock Character LCD Keypad remote annunciator with metal enclosure and key lock remote annucniator capable of displaying alarms supervisory and trouble status for 16 zones Amp Intelligent power supply Form C Relay Card Printer Card Optional Rack Mount Communications Bridge 1 may be added for remote IP Communicator Interface Module used in pairs to convert P Link over multimode fiber optional rack mount 2 OF 3 8830001 REV C11 13PRINTED IN USAPFC 6075FIRE ALARM CONTROL PANELfirealarmresources com Circuit Diagram Monitoring Alarm Amp NAC Candela Mount Stobe or Candela or Strobe Horn Annunciator Expander Annunciator Device Enclosure Output I O Loop Base Detector Sounder Detector Heat Detector Base Detector Relay Detector Relay Output Contact Circuit Contact Contact Station Zone Detector Monoxide 3 OF 3 8830001 REV C11 13PRINTED IN USAPFC 6075FIRE ALARM CONTROL PANELfirealarmresources com

Related Files