Potter PFC-6800 127 Expandable to 1,016 Point Addressable Fire Alarm Control Panel

File Preview
File Preview
Click below to download for free

Text Preview

Features points expandable to 1,016 by use of seven SLCE cards Amp Power Supply NACs regulated rated at 3 amps each multifunctional input output I O circuits for flexibility rated at amp each synchronization for Potter AMSECO Gentex Cooper and System Sensor Software zones for versatile installation options x 40 LCD and keypad for ease of operation Dual P Link communication circuits for annunciation and Optional dual line digital alarm communicator reports by panel or point ID port for programming reporting and network system status reports and event information IP communicator supports report by point zone or panel W x H x D 17 5 8 x 26 x 3 3 4 Specs Mains amps 120 VAC 50 60Hz amps 240 VAC 50 60Hz mA Standby mA Alarm Fire Dept of Approval includes a 5 year warranty PFC 6800 is a single loop expandable to eight loop analog addressable fire alarm control panel The panel utilizes the Potter Nohmi device that has a complete line of initiating and control devices The SLC is capable of 50 ohms of resistance and does not require the use twisted or shielded wire The on board Signaling Line Circuit SLC supports 127 of any combination of smoke sensors heat detectors or Up to six additional SLC cards may be added in the control panel Some or all of the SLC cards may be remotely installed to provide additional 127 points bringing the total system capacity to 1,016 points PFC 6800 has a metal cabinet with a key lock and a dead front standard The cabinet will house 8 Ah or 18 Ah batteries and the panel has power to charge up to 55 Ah batteries The large LCD and window allows easy viewing of the system status and the standard LEDs The allows easy operation and navigation of the system menu panel has auto programming learn mode that will not affect the existing system when adding or deleting a device The system is capable of software zones cross zoning and counting zones The panel is fully programmed from a PC based software program that will work with XP Vista or Windows 7.0 operating systems PFC 6800 has an Ethernet connection for programming network connectivity and IP reporting communicator The system uses a simple cable for connecting a PC to the panel In addition the system may be connected to a building network and programmed while on the The system has a built in e mail function and will send system E mail reminders The IP communicator is listed with the Sur Gard III IP panel will support P Link devices which include the RA 6075 RA 6500 and LED 16 Annunciators RLY 5 Relay Module SPG 1000 Parallel Gateway printer card FCB 1000 Remote Ethernet IP connection DRV 50 LED driver for 50 LEDs PSN 1000 Remote Power 10 Amp and FIB 1000 P Link Fiber Interface Module In addition the panel allows for the installation of the UD 1000 dual line line digital alarm communicator transmitter DACT The UD 1000 is programmable for a single line or dual line and is compatible Ademco Contact ID or SIA DCS protocols SLCE 127 may be installed with 6,500 feet of the control panel and may be installed in the AE 8 eight slot or AE 14 fourteen slot expansion Another option is to install the SLCE 127 in the PSN 1000E intelligent power supply to allow remote installation of the loop adder and synchronized notification circuits Each PSN 1000 acts as a P Link repeater and will repeat the communication to allow the installation the remote loop thousands of feet from the main control panel complete system may be converted to Class A with a CA 6500 module The CA 6500 provides the hardware necessary to convert the annunciators through the Potter P Link connection protocol the NACs and the SLC to Class A operation Electric Signal Company LLC St Louis MO Cust Service 866 956 1211 Tech Support 866 240 1870 Canada 888 882 1833 www pottersignal com 1 OF 3 8830029 REV D2 18PRINTED IN USAPFC 6800FIRE ALARM CONTROL PANELfirealarmresources com Loop Accessories control panel may be connected with up to 1,016 addressable devices or modules in any combination The SLC is not restricted by any wire requirements and may be wired with any wire that complies with the NEC Loop Devices Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot Analog Photo Electric Smoke Heat Detector a smoke detector with a listed obscuration of 1.02 to percent obscuration and a fixed temperature 135 Fahrenheit heat detector Fixed Temperature Heat Detector that is selectable from 135 F to 185 Rate or Rise Heat Detector that has a fixed temperature selection from 135 and 174 and also will if the temperature increase 12 15 in one minute Duct Smoke Detector round base that is mounted to an electrical box and wired for connection of one of the above sensors round base that is mounted to an electrical box and wired for connection of one of the above sensors base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop Relay Base that contains two relays controlled by the SLC One relay is rated at 8 amps at 240 and the other is rated at 2 amps 240 VAC 30 VDC Sounder Base that contains an addressable sounder module that may be configured for local group all call The sounder follows the pattern sent to the device Contact Module provides a small foot print contact module for mounting inside an enclosure Action Addressable Pull Station Action Addressable Pull Station Contact Module is a standard contact module with an LED that mounts into a 4 square electrical box Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode Relay Module provides two form C relays that simultaneously active when the module is triggered by the panel Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC Output Module switches monitored power and is activated by the control panel Input Zone Module is used to connect conventional smoke detectors Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the Devices remote annunciator with a metal enclosure and key lock Character LCD Keypad remote annunciator with metal enclosure and key lock remote annucniator capable of displaying alarms supervisory and trouble status for 16 zones Amp Intelligent power supply Form C Relay Card Printer Card Optional Rack Mount Communications Bridge 1 may be added for remote IP Communicator Interface Module used in pairs to convert P Link over multimode fiber optional rack mount 2 OF 3 8830029 REV D2 18PRINTED IN USAPFC 6800FIRE ALARM CONTROL PANELfirealarmresources com Circuit Diagram Communicator Monitoring NAC circuits Amp each Candela Strobe or Strobe Horn Candela or Strobe Horn Alarm Communicator Annunciator Annunciator 1000 E Supply Line Expander A Input Output Circuits to 7 per panel Loop Base Detector Sounder Detector Heat Detector Base Detector Relay Detector Relay Output Contact Circuit Zone Detector Contact Monoxide Contact Station 3 OF 3 8830029 REV D2 18PRINTED IN USAPFC 6800FIRE ALARM CONTROL PANELfirealarmresources com

Related Files