Potter WTK Water Test Kit

File Preview
File Preview
Click below to download for free

File Data

Name potter-wtk-water-test-kit-5806937241.pdf
Type PDF
Size 815.79 KB
Downloads

Text Preview

Includes 1 each 120 cc sample bottle Instruction sheet Prepaid shipping label U S Only Pre printed return mailing label Laboratory analysis of returned water sample number 1119178 kit is designed to conform to the requirements of NFPA 13 2002 4.3 the building owner or their agent to provide an Owners Certificate any knowledge of the water supply used for the sprinkler system well as complying with 23.1.5 requiring the water supply to be evaluated MIC or other corrosive properties receiving the sample the lab will establish a chain of custody and the sample for bacterium extraction Five groups of bacteria will cultured Heterotrophic Bacterium which determines if the majority of are anaerobic without air or aerobic with air in nature Slime Bacterium aids in tubercle formation Iron Related Bacterium oxidizing and reducing bacterium Sulfate Reducing Bacterium pit corrosion and Acid Producing Bacterium causes pit corrosion Iron testing will also be performed to determine general corrosion of system The testing will take approximately 9 days to allow for culture growth A full written report will be provided approximately business days after testing is started analysis of an existing sprinkler system should include 2 water 1 each collected at the beginning of the system or riser and from the of system new or proposed sprinkler systems only 1 sample from the source water necessary collected from dry systems can also be tested Sample Retrieval Return Procedure The sample must be received by Potter within 72 hours after it is from the sprinkler system If obtaining a sample from a sprinkler system use all precautions to prevent an unwanted waterflow alarm Open the system to be tested Let the water run for approximately seconds Fill a 120 cc bottle to the top Cap bottle tightly and tape cap to bottle Complete the sample identification section of this document Place sample bottle and this completed document into the original Ship to Potter Electric using the enclosed pre paid UPS Second A full report will be issued within 15 business days after testing carton form started testing procedures have been tested against the appropriate Type Culture Collection A T C C strains for each specific group bacterium Iron test uses the 1 10 Phenanthroline method adopted from Test Methods of Water and Wastewater 15th edition 201 1980 Identification This section MUST be filled out completely and returned with sample bottle Requesting Test State Zip you would like report sent via email Tested Riser State Zip Information circle one Wet Dry FPS Age Total of Risers Sq Ft approx of Floors Type of Pipe circle TW Sch 40 Black Galv Threaded Grooved System Treatment Sample Information sample collected Time in system where obtained collected by description remarks Electric Signal Company LLC St Louis MO Phone 866 956 0988 Canada 888 882 1833 www pottersignal com 1 OF 1 IN USAMFG 5400608 REV F4 14WTKWATER TEST KITfirealarmresources com

Related Files