Cerberus Pyrotronics CSM-4 Controllable Signal Module

File Preview
File Preview
Click below to download for free

File Data

Name cerberus-pyrotronics-csm-4-controllable-signal-module-6589403127.pdf
Type PDF
Size 886.03 KB
Downloads

Text Preview

CSM 4 Signal Releasing Module AND ARCHITECT SPECIFICATIONS Supervised Alarm Notification Appliance Circuits Operates Audible or Visual Devices 2 Class A Style Z or Class B StyleY Circuits 24 VDC 1.5 Amps Per Circuit City Tie or Lease Line Output Releasing Service Fully Programmable Coded Audibles On Board Microprocessor March Time Uniform Code 3 Selectable Degrade Operation Silencable Non Silencable Option Automatic Manual Control Circuits Power Limited Per NEC 760 Listed ULC Listed CSFM NYMEA FM Approved NFPA 13 Pre Action and Deluge NFPA 2001 FM 200 Releasing NFPA 12A Halon Releasing Controllable Signal Module CSM 4 provides two fully programmable notification appliance circuits CSM 4 supplies two Class B Style Y or Class A Style type output circuits for the supervision and control of audible or visual notification appliances such as bells strobes etc Each circuit can provide up to amps 24 VDC of current to power indicating appli output on a CSM 4 may be configured as either a connection to a local energy type Master City or a supervised connection to a Leased Line remote system CSM 4 circuits may also be configured pre action or deluge releasing service per NFPA 13 agent releasing Halon FM 200 per NFPA and NFPA 2001 circuit or output may be controlled automatically the MXL program logic or manually using the MXL Automatic control may also be time based Each or output can be manually or the MXL keypad When any circuit or output has the MXL LCD annunciator will indicate affected circuit or output and the System LED will illuminate until the circuit or output has returned to the condition CSM 4 contains an on board microprocessor which notification circuit outputs to function in a degrade even if the main MXL processor or the local network link has failed Each circuit degrade of operation can be separately configured to respond an alarm in the following manner OFF ON CONTIN or 1 SECOND ON 1 SECOND OFF In a degrade a CSM 4 will respond to an alarm from any Intelli ALD initiating device or Conventional Zone connected to the same network node notification appliance circuit outputs may be to provide a coded march time or uniform 3 output equipment is approved for operation over the tempera range of 0 to 49 NUMBER and Architect Specifications and Architect Specifications Appliance Circuits shall be provided by a Pyrotronics Model CSM 4 plug in controllable module The unit shall provide two alarm notifica application circuits which may be configured as either A Style Z or Class B Style Y Each circuit will be of activating up to 1.5 amps of listed audible or notification appliances These circuits shall also be of being configured for activation of a local energy City connection or polarity reversal type Leased Line circuit shall also be capable of being configured to a solenoid for pre action or deluge releasing per NFPA 13 as well as extinguishing agent Halon FM 200 per NFPA 12A and NFPA 2001 notification appliance circuits shall be capable of a mode of operation in the event of main processor or loss of network communication notification appliance circuits shall be capable of activation or de activation through control by or time based programming contained in the control They shall also be capable of manual activation or using the system keypad Disarming any or output shall result in the alphanumeric display the circuit or output which has been disarmed as as the illumination of the Partial Disable LED CSM 4 shall be a plug in type module using gold edge connectors to interface with the MOM 2 or expansion card cages It shall occupy one half slot the card cages Notification circuit City Tie and Leased power shall be provided to the CSM 4 through the control power supply or through the supervised power supplies Data Data Board Installation Slots municipal tie and leased line applications require the interface module notification appliances and leased line applications are limited CONNECTIONS FOR NOTIFYING NFPA 72 Local Set switches S3 and S4 and jumpers G1 and G2 as in Table 2 All wiring must be in accordance with Article 760 or NEC local building codes Both circuits are power limited to NFPA 70 per NEC 760 Electrical Ratings End of line device to 31 VDC 12mA max to 31 VDC 1.5A max Cerberus Pyrotronics EOL device 2.2K watt 140 820380 Line Resistance ohms max Loop Wiring for Supervised Notifying Circuit shown in Normal State Line Circuits are Power per NEC 760 Resistance 2K 5K Polarity shown in supervisory state The total loop resistance from the LLM 1 to the Municipal Tie including the 14.5 OHMS in the Municipal Tie should not exceed 22.5 OHMS Either circuit may be used Municipal Tie circuits are not power limited Loop Wiring of Supervised Municipal Tie NOTIFICATION APPLIANCES Horns with Strobe Stroke Bells Leased Line Circuit Strobes Strobes Strobes Plate Electro Mech Horns Strobes Horns Strobes Module Bell Strobe Plate Horns Whoop Horns Mini Horns 8 Tone CONNECTIONS FOR MUNICIPAL TIE 72 Set switches S3 and S4 and jumpers G1 and G2 as in Table 2 All wiring must be in accordance with Article 760 of NEC local building codes Both circuits are not power limited Electrical Ratings Coil Current Current total loop resistance from the LLM 1 to the Municipal including the 14.5 ohms in the Municipal Tie should exceed 22.5 ohms ohms to 320mA DC momentary DC to 31 VDC Minimum emergency power hour standby minute alarm CONNECTIONS FOR LEASED LINE 72 Remote Station Set switches S3 and S4 and jumpers G1 and G2 as in Table 2 When a CSM 4 circuit is used as a Leased Line trouble SW1 and SW2 on switch S2 must be set These permit the default trouble bus to activate the line Refer to TABLE 3 to set them All wiring must be in accordance with Article 760 of NEC Both Leased Line circuits are power limited to NFPA 70 local builsing codes NEC Article 760 Leased Line circuit rating 24 VDC open circuit Load be a compatible polarity reversal labeled remote receiver unit current circuit resistance 2K to 5K ohms to 9mA alarm supervisory Minimum emergency power hour standby 5 minute alarm

Related Files