Siemens Desigo Fire Safety System A comprehensive fire-protection system (for Canada), Data Sheet
File Preview
Click below to download for free
Click below to download for free
File Data
Name | siemens-desigo-fire-safety-system-a-comprehensive-fire-protection-system-for-canada-data-sheet-3809752461.pdf |
---|---|
Type | |
Size | 1.24 MB |
Downloads |
Text Preview
s Fire Safety System comprehensive fire protection system AND ENGINEER SPECIFICATIONS Sheet Safety Security Products Standard 252 point and 504 point systems Remote viewing for the 252 and 504 point systems One 1 or 2 two height enclosures Powerful but user friendly interface Softkey buttons RS interface Four way navigation menu with capability Primary regulated power 170 Watts is rated at 6.5 Amps 300 Watts is rated at 11.5 Amps Universal AC power input 120VAC or 240VAC 50 60Hz 2.0A max Fully field programmable via a PC Supervised remote printer via the Peripheral Module for the 252 504 point systems Menu driven operator commands 5,000 event history logging capability on line and off line reports Off line reports can be viewed the custom programming tool EEPROM software compatible Multiple levels of password protection Automatic environmental for smoke detectors Pre alarm operation Alarm verification by device or zone Degrade mode operation Logic controlled output functions Optional city tie leased line module Distributed processing Emergency Alarm events for CO per NFPA 720 for the 252 504 point systems Optional notification appliance circuit expansion module Up to 3.0 amps 24VDC load per output Module used for 252 504 point systems per NFPA 72 Detector Sensitivity Readout Printout NEC 760 power limited circuits ULC Listed ULC compliant 3010 CSFM 7165 0067 0259 FDNY 6104 Approved Built in strobe synchronization protocol Global annunciation and control Several relay commands Alarm Trouble Supervisory etc Light emitting diodes LEDs for Alarm Supervisory Silenced Fault Trouble and system LEDs Alarm command has a larger distinctive LED LED option provides LED annunciation of activity SureWireTM addressable loop technology Patented polarity insensitive detection circuits Intelligent analog detection A or B Supports FirePrintTM detection Supports single person Test Sprinkler Supervision End user screens Multiple command stations Supports pre action deluge and releasing for 504 point systems Releasing valve monitoring Backlit liquid crystal display LCD Overview Desigo Fire Safety System a comprehensive fire system from Siemens Fire Safety is a advanced fire and life safety system Desigo system provides easy operation via its soft keys a backlit LCD screen and a 4 navigation push button all located in the portion of each panel the use of its unique multiprocessor along with its ability to utilize intelligent devices Desigo epitomizes a flexible and configurable fire system SureWireTM technology is supported by Desigo Canada Limited is ideally suited for is ideally suited for mid market via its 252 or 504 point addressable fire panel FACP which are each networkable conjunction with these new and improved FACPs is a line of intelligent detectors For example Multi Criteria Fire CO Detector with ASAtechnologyTM cutting edge technology for specialized applications as carbon monoxide detection compared to detectors while the Photoelectric Smoke uses microcontroller circuitry and surface mount for maximum reliability Fire Safety System 6800C Components 504 point Desigo Fire Safety system 504 point Desigo Fire Safety system Desigo Fire Safety Model FC2025 252 point and 504 point addressable FACP is designed to meet fire protection needs of mid size buildings advanced panel offers features typically required in buildings in a package that is easy to install and priced Additionally Models FC2025 and are networkable allowing the systems to fulfill growing fire protection needs of the building following Desigo Fire Safety system components are in the 252 point 504 point FACP Operating units Periphery boards Power supplies System enclosures Operating Unit w LEDs Operating Unit Interface Unit Operating Interface Unit Model FCM2018 U2 or the Interface Unit with LEDs Model FCM2035 U2 the operator interface and central microprocessor for Fire Terminal Model FT2050 and Desigo FACPs FC2025 and FC2050 FCM2018 U2 or Model FCM2035 U2 provides capability for each end user to efficiently events to quickly control the signaling SCs of the corresponding FACP and to permit a reset of the respective system Detailed about the nature and location of the events also be displayed via a 5.1 cm 12.1 cm backlit screen FCM2018 U2 or Model FCM2035 U2 contains the program configuration created in The controller in each interface module provides system logic and supervision Operating Unit allows for connection to the Remote Module Model FCA2018 U1 and or the Terminal Displays Models FT2014 U2 R2 R2 Canada Limited board for 252 point Fire Safety system board for 504 point Fire Safety system Boards periphery boards Models FCI2016 U1 and FCI2017 encompass the key components for operating the panels Models FC2025 and FC2050 module operates and monitors input device identity well as controls the signaling line circuits that with smoke detectors and other field i e FDnet periphery board is equipped with two 2 B Style Y or 1 Class A Style NAC providing 24VDC nominal up to 3A per circuit audible visual signaling circuits periphery boards mount directly on the enclosure boxes of the Model FC2025 and Model FC2025 panels Models FCI2016 U1 FCI2017 U1 provide 2 parallel auxiliary powered short circuit protected regulated 24VDC 1.5A max that supply to external devices or modules FCnet Network Module FCnet Network Module SAFEDLINK network module Model FN2001 U1 is to network up to 16 FACPs or fire terminal units FT2050 via the FCnet system bus The network module is plugged into the Operating Model FCM2018 U2 or Model FCM2035 U2 FN2001 U1 supports networking the following systems Model FC2025 Model FC2050 Model FT2050 Model FN2001 U1 connects to system bus inputs and and the module has ground fault monitoring as as an integrated degrade mode function networking is accomplished with one 1 module simple loop trouble per panel There is isolation between the system bus and the FACP Components continued Terminal and equipment Fire Terminal Model FT2050 consists of the Fire Board Model FTI2001 U1 the Operating Model FCM2018 U2 or Model FCM2035 U2 a one height unit enclosure Model FT2050 terminal contains a backlit 5.1 12.1 cm LCD screen as well as a 4 four navigation push button An audible will sound there are events on the display of each operating unit categorizes events type providing a separate event tab for Alarm Alarm Supervisory and Trouble events quantity of active events of each type is listed in event tab The display provides two 2 full lines text message for each event event can have a 40 character custom message the locatio