Siemens Inner Doors for FHB2001 and FHB2002 Backboxes, Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Installation Instructions FHD2004 U1 and FHD2005 U1 Doors for FHB2001 and FHB2002 Backboxes Models FHD2004 U1 and FHD2005 U1 Inner Doors from Siemens Industry Inc used with FHB2001 U1 R1 and FHB2002 U1 R1 Backboxes The FHD2004 U1 door has an opening for installing a PMI or system switches LEDs The inner door is solid and can function as a dead front Both doors are 1 and FHD2005 Inner Doors and FHD2004 Doors are for indoor use only in dry environments installation of the inner door s is typically done before the outer door is installed FHB2001 uses only one inner door but the FHB2002 uses up to two inner doors following hardware kit is provided with the FHD2004 U1 sure to retain the 8 10 32 kep lock nuts for mounting modules or blank plates on inner door an FHB2002 backbox is used with only an upper inner door the backbox can a set of BTX 1 33AH batteries If an inner door is used on the bottom an FHB2002 backbox the backbox can only accommodate a set of BP 61 18AH A6V10335929 a en Inc Inc Inc Industry Inc Inc TTTTTececececechnologies Di Di Di Division Di the Inner Door to Figure 2 three of the four 8 32 x 5 16 screws provided in the bottom three holes the door on the left side of the enclosure and tighten them a few turns the inner door into position under the screws the door making certain the spring loaded fastener fits in the hole on right side of the enclosure Screw down the fastener to secure it in the remaining 8 32 x 5 16 screw in the top hole and tighten all four securely steps 1 4 if there is an additional inner door 2 the Inner Door s Strap Installation Door Model FHD2004 is shipped with a ground strap in the bag with the four x 5 16 screws used to mount the door in place Model FHD2005 does not a ground strap enclosure Model FHB2001 the stud for securing the ground strap is located on the side of the enclosure near the top In enclosure Model FHB2002 the stud securing the ground strap is located on the left hand side of the enclosure near center The stud in the FHB2001 and FHB2002 enclosures that comes with a strap installed on it is used for both the inner and outer door ground straps to Figure 3 which illustrates ground strap installation in an FHB2001 Ground strap installation in an FHB2002 enclosure is done in the way Figure 4 shows the location of the ground strap stud in the enclosure one end of the ground strap on the stud in the enclosure marked secure it in place between the two 10 32 kep nuts the other end of the ground strap between the PMI or other module on the inner door and the kep nut used to secure it in place Industry Inc Technologies Division A6V10335929 a en OF PMI 3 the Ground Strap on the FHD 2004 Inner Door and FHB2001 Backbox STRAP 4 of Ground Strap on the FHB2002 Backbox Industry Inc Technologies Division A6V10335929 a en inner doors can be used with FHB2001 U1 R1 and FHB2002 U1 R1 only inner doors can be used with FHB2002 U1 R1 backboxes only x 9 16 x 13 1 4 x 9 16 x 13 1 4 Industry Inc Technologies Division Park NJ Canada Limited Technologies Division Kenview Boulevard Ontario L6T 5E4 Canada

Related Files