Siemens MID-16 Input Module, Installation Instructions

File Preview
File Preview
Click below to download for free

File Data

Name siemens-mid-16-input-module-installation-instructions-0849327165.pdf
Type PDF
Size 630.42 KB
Downloads

Text Preview

Installation Instructions MID 16 Module Model MID 16 from Siemens Industry provides sixteen general purpose inputs user defined operations for the MXL all system power before installation battery and then AC To power up the AC first then the battery Model MID 16 is controlled by the MOI 7 See P N 315 092799 Up to eight can be used with an MOI 7 Mount the MID 16 in one module space using four screws provided MID 16 monitors a maximum of sixteen The inputs are activated by connecting positive voltage to the input terminal The of each individual input is defined by usage assigned to it in the CSG M See CSG M Manual P N 315 090381 for list of usages can be mixed with MOD 16s P N 315 090830 up to a maximum of modules each on the same MOI 7 do not interact with MOD 16s by logical function as defined in the MID 16s can also supervise lamps that are controlled MOD 16 outputs additional information on the MXL MXLV refer to the MXL MXLVManual 315 092036 Connect the MID 16 to the module to its left the 10 position ribbon cable P N 555 provided This module may be either MOI 7 MOD 16 or MID 16 a connection to a module on another rail is use the optional cable P N 555 INFORMATION ratings voltage range impedance current VDC ohms 24VDC Industry Inc Technologies Division Park NJ 315 091860 8 Building Technologies Ltd Safety Security Products Kenview Boulevard Ontario 5E4 Canada COMMON OF SUPPLY OR TB1 10 PREVIOUS MOD 16 OR MID 16 TB1 9 OF NEXT OR MID 16 1 8 PROVIDES FIRST 8 INPUTS NOT USE CABLE P N 555 190940 IS IF THE CONNECTION TO ANOTHER RAIL IN THE USE OPTIONAL P N 555 190941 PREVIOUS MID 16 MOI 7 CABLE 555 190940 NEXT OR MID 16 P N 555 190940 1 8 PROVIDES SECOND INPUTS IMPEDANCE 8K OHMS INPUT CURRENT INPUT TO ONE OF THE FOLLOWING ANY AUXILIARY POWER SUPPLY LISTED FOR FIRE PROTECTION USE COMMON OF SUPPLY OR TB2 10 PREVIOUS MOD 16 OR MID 16 TB2 9 OF NEXT OR MID 16 18 AWG minimum for all input connections 14 AWG minimum for supply connections the enclosure must be within 20 feet rigid conduit and must not leave the room 1 9 and 10 TB2 9 and 10 For additional information see MOI 7 module All wiring must be in accordance with NEC 760 All wiring must meet local codes and satisfy authority having jurisdiction over the All wiring to MID 16 MOD 16 or MOI 7 non modules is unsupervised Any wiring P N 315 092799 A maximum of 8 MID 16s can be used the MOI 7 P1 is connected in parallel with TB1 P2 is connected in parallel with TB2 315 091860 8 1 Connection

Related Files