System Sensor 400 Series Plug-in Smoke Detectors

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-400-series-plug-in-smoke-detectors-1084763529.pdf
Type PDF
Size 790.15 KB
Downloads

Text Preview

400 Series Plug In Detectors Sensor 400 Series plug in thermal detectors the performance criteria designated by Laboratories Low standby current Two visible LEDs in standby and provide a 360 field angle Wide variety of mounting bases with built in shorting spring Detector head plugs easily into base Built in test switch Field sensitivity metering of detector to meet the requirements NFPA 72 Built in tamper resistant feature SEMS screws for easy wiring Optional recessed mounting 5451 thermal detector meets the needs for applications rapid response is vital and rapid temperature increases would be caused by a fire emergency detector contains a unique dual thermistor heat sensing circuit provides maximum performance and solid state reliability It an alarm in response to both rapid rate of rise conditions in excess of 15 per minute and fixed heat 135 This the heat detector to communicate an alarm to the central panel prior to reaching its fixed set point for high rates of providing a timely response to both rapid and slow temperature key features include a recessed mounting option a variety mounting bases and a full line of optional accessories Listings Series Plug In Smoke Detector Specifications Specifications Temperature Range Range Point Detector Spacing 8.1 cm H 4.0 10.2 cm Dia unflanged base 6.2 15.7 cm Dia flanged base lb 136 g to 100 0 to 38 to 93 RH non condensing retardant Noryl plastic 57.2 or 15 rate of rise smooth ceilings as defined in NFPA 72 spacing of 50 feet 2500 sq ft may be used Other spacing may be used on ceiling height high air movements and other conditions or response requirements maximum Current Voltage Alarm Current Mounting base dependent see Mounting Base Selection Guide below Base Selection Guide Model Number Resistor Type contingent on panel compatibility be limited by control panel Draw Alarm mA to 100 VDC Flangeless base Although B401 bases are capable operating at 12 and 24 VDC they be used with the 5451 in 12 applications Box Selection Guide Gang Octagon Octagon Square mm mm mm depth contingent on base and wire size Refer to National Electrical Code of local applicable codes for appropriate recommendations FAULT TOLERANT WIRING MOD400R Field Sensitivity Module can be used with standard DC voltmeter or to check the sensitivity of System Sensor detectors NFPA 72 requirement for testing Information No heat detector with rate of rise Alarm point at 57.2 135 Must be mounted to one of the 400 Series Bases listed in Mounting Base annunciator for 2 or 4 wire systems 3 to 32 V Use with ion and photo plug in detectors Fits standard U S single gang electrical box sensitivity test tool See above Use with most analog or digital multimeters Satisfies requirement of NFPA 72 for sensitivity testing above of line relay for power supervision 12 24 VDC 4 wire only protective dust cover for plug in 400 Series magnet magnet with 32 inch telescoping handle removal tool Allows installation and or removal of detector heads from base in high ceiling installations pole for XR5 Comes in three 5 ft sections Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 System Sensor specifications subject to change without notice Visit systemsensor com for product information including the latest version of this data sheet 3 11 2651

Related Files