Notifier NION-232-200 Product Installation Document

File Preview
File Preview
Click below to download for free

File Data

Name notifier-nion-232-200-product-installation-document-9582637140.pdf
Type PDF
Size 1.02 MB
Downloads

Text Preview

NION 232 200 Installation Document document covers the procedures and specifications for installing the above listed unit and when information regarding configuration on the monitored device For more detailed configura and operation information refer to Network Installation Manual Echelon Local Area Server Manual BCI 3 Manual as appropriate of the Serial NION 232B Serial NION 232B Network Input Output Node is the EIA 232 interface used with the network All of the components are based on LonWorks cid 153 Local Operating Network technologies The Serial NION 232B transparent or interpreted communications between the workstation and control panels Unless otherwise full control capabilities are available for each interface Check specific connections for details NION connects a LonWorks cid 153 FT 10 or FO 10 network and the RS 232 port of control panels It provides a two way communication channel for RS 232 serial data when connected to a control panel NIONs are to the type of network to which they connect FT 10 or FO 10 The transceiver type must be specified and separately when ordering the NION NION can be powered by any 24VDC power limited source with battery backup which is UL listed for use with protective signaling units NION mounts in an enclosure NIS CAB 1 or CHS 4L in CAB 3 series enclosure with conduit knockout Requirements NION 232B can be installed in the following environmental conditions range of 0 to 49 32 cid 176 F 120 cid 176 F humidity non condensing at 30 86 cid 176 F NION 232B is designed to be installed on a wall within 20 feet of the control panel in the same room The of hardware used is at the discretion of the installer but must be in accordance with local code requirements Board 232 Status Net Ser Rec Ser Fail 1 2 Output 1 2 Configura Switch OutputsIn General 50827 NION 232B 200 Installation Rev A 9 30 98 Rev A 50827 ECN 98 113 Manuals Online Communication Description baud rate parity and data bits of the NION 232B must be equal to those of the RS 232 serial port of the panel The NION 232B comes from the factory preset for the application it was ordered to fill These are made on switch S2 it becomes necessary to change any of these settings use the chart below Baud Rate Switch Position 4 Switch Position 5 Switch Position 6 On Notifier equipment operates at 2400 baud Position 2 Position 3 600 Parity None Odd Even Data Bits 8 7 Position 1 If the device connected to the NION calls for 9 data bits then the NION must be set to 8 bits with either Even or Odd parity S2 Settings for the NION 232B RS 232 Configuration Power Requirements NION 232B requires 24 VDC 0.080 A nominal and battery backup in accordance with local code It can be powered by any power limited source with battery backup which is UL listed for use with protective signaling units Communications with Notifier Products RS 232 settings for any Notifier panel are Rate 2400 Data Bits 7 Stop Bits 1 Parity Even It is recommended that the installer conform to local code requirements when all wiring All power connections must be non resettable Refer to the Notifier catalog for specific part numbers and ordering information for each Always remove power from the NION before making any changes to switch and removing or installing option modules SMX network modules and upgrade chips or damage may result Always observe ESD protection 50827 NION 232B 200 Installation Rev A 9 30 98 Manuals Online Connections with the AFP200 Control Panel NION 200 must be connected to the CPU circuit board of the AFP200 panel Serial communication wires be connected to the TB4 connector EIA 232 For specific connections refer to Figure NION 200 AFP200 Diagram The NION should be mounted within 20ft of the panel with all connections run in conduit the NION from the AFP200 Control Panel NION should use terminals 3 24 and 4 Common of the TB1 connector to get the auxiliary power from the panel This power source is power limited and non resettable For specific connections refer to Figure Wiring Diagram CPU Circuit Board Wiring Diagram the AFP200 Control Panel AFP200 Control Panel must be configured for communication with the NION 200 This is done through the programming utility on the AFP200 panel This section describes the specific changes needed in the panel For general programming procedures on the AFP200 refer to the AFP200 Instruction Manual Mode of Operation must be set for proper communication with the NION This is done during panel pro under the system parameters section 7 SYSTEM Under the SYSTEM selection the mode must be set Local Terminal Mode LocT Use only wire for power limited systems limited wire runs use type FPLR FPLP FPL equivalent cabling per NEC 760 Manuals Online 50827 NION 232B 200 Installation Rev A 9 30 98

Related Files