Potter Fireray One Auto-aligning Beam Detector

File Preview
File Preview
Click below to download for free

File Data

Name potter-fireray-one-auto-aligning-beam-detector-4017635928.pdf
Type PDF
Size 5.79 MB
Downloads

Text Preview

Fireray One no specialist tools or knowledge needed for installation and operation the Fireray is a standalone beam detector that prioritises ease of installation the Fireray One it couldn be easier to bring the benefits of beam detection to application One Minute Auto Alignment just steer the laser onto the Reflector at the flick of a switch it aligns itself 8 times faster than detectors One person installation everything can be done by one person One standalone product no specialist tools required minimal prior knowledge training needed Challenge One effective protection standalone beam detector all the benefits of Fireray beam detection point of wiring and Movement Tracking compensates for building movement to maintain alignment installation of the building cause other beam to misalign and in nuisance alarms specification performance range method protocol Movement Tracking Compensation Cancellation Technology wavelength smoke detection laser laser alignment Beam Phasing output user settings response threshold levels to Alarm to Fault features user interface status indication status indication to 164ft 0 to 50m to 394ft 0 to 120m with Reflective Long Range Kit assisted Auto Alignment Manual alignment optional setting check Box search Adjust and Center for natural shifts in alignment from building movement for gradual build up of contamination on the optical surfaces for high levels of sunlight and artificial lighting near infrared invisible visible Class IIIa 5mW beam detectors to be mounted facing each other with the reflectors in the middle false alarms caused by crosstalk between beams Alarm and Fault relays VFCO 0.5A 30 VDC 1.25dB Fastest response to smoke 1.87dB Default value 3.46dB High immunity to false alarms slow response to smoke 8.23dB Highest immunity to false alarms slowest response to smoke via the integrated user interface seconds for momentary partial obstruction of the beam path seconds for momentary obstruction of the beam path mode switch alignment directional buttons and configuration switches for alarm response Green LEDs and 1 Yellow LED operation Green LED flashing every 10 seconds condition Red LED flashing every 10 seconds condition Yellow LED flashing every 10 seconds for obscuration or every 5 seconds for front face with enclosed optics Cleaning the optics does not affect alignment parameters distance between Detector Reflector path clearance spacing between detectors location dimensions dimensions weight arrangement color specifications voltage current constant all operational modes wiring gauge and type entry and maintenance test specifications temperature 4 to 131 20 to 55 temperature 40 to 185 40 to 85 humidity non condensing or icing 0 to 93 rating IP55 flammability rating UL94 V0 polycarbonate figures are quoted for 77 25 information number and Maintenance Kit Detector adjustment bracket Fireray One Protective cage Reflector Adjustment Bracket Reflector Adjustment Bracket wall bracket white wall bracket black One Anti condensation heater Anti condensation heater One Back Box Gang Electrical Box Cover Plate to 164ft 5 to 50m to 394ft 50 to 120m with Reflective Long Range Kit 1m in diameter from center line between Detector and Reflector 18.3m maximum as per NFPA 72 the ceiling jet flow top 10 of the floor to ceiling height unless otherwise stipulated 5.12 x Height 7.13 x Depth 5.28 W 130mm x H 181mm x D 134mm see diagram to 164.0ft 50m separation distance 3.94 x 3.94 x 0.36 100mm x 100mm x 9mm to 393.6ft 120m separation distance Four reflectors 7.88 x 7.88 x 0.36 200mm x 200mm x 9mm square pattern 1.55lbs 0.7 kg Reflector 0.22lbs 0.1 kg Beam Phasing allows for Detectors to face each other with the reflectors in the middle RAL9016 UV stable to 36 VDC operational modes 5mA Fast alignment mode 33mA core dedicated 24 to 14 AWG 0.5 to 1.6mm compatible with fireproof and non fireproof cable meeting local installation standards knock out locations capable of accepting M20 or glands drill out locations capable of accepting glands up to 0.82 21mm diameter alarm test using Commissioning and Maintenance Kit accessory specifications level Rapid obscuration 2 seconds angular alignment of Reflective Detector with adjustment bracket accessory angular misalignment of Reflective Detector angular misalignment of Reflector One Back Box 1260 000 Cage PN 1100 000 Wall Bracket Black 1031 000 Reflector Adjustment PN 1040 000 One 134mm Range Kit PN 1010 000 130mm 9mm 100mm One 164ft 50m detection range Long Range Kit 394ft 120m detection range cid 29 cid 28 cid 30 cid 27 CALIF E M A R cid 30 H cid 25 Cancellation Technology Patent No GB2513366 Beam Phasing Patent pending Patent pending mounted according to manufactures guidelines www ffeuk com Limited 1455 Jamike Ave Ste 200 Erlanger KY 41018 3147 USA 1 859 957 1570 america ffeuk com and wiring information are provided for information only and are believed to be accurate FFE Ltd assumes no responsibility for their use Data and design are subject to change notice Installation and wiring instructions are shipped with the products and should always be used for actual installation For more information contact your Sales Representative No 24 0191 03

Related Files