System Sensor 100 Series Smoke Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | system-sensor-100-series-smoke-detectors-6735481902.pdf |
---|---|
Type | |
Size | 1.32 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS Direct Wire Ionization Detector SENSOR Division of Pittway 3825 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 inches 140 mm including adapter bracket 1.7 inches 43 mm Temperature Range Humidity Range Alarm Ratings Voltage oz 150 g to 120 cid 176 F 0 cid 176 to 50 cid 176 C to 93 Relative Humidity Noncondensing by momentary power interruption Ripple Voltage Capacitance Standby Current Ratings Voltage Time Time or 24 VDC 8.5 VDC 35 VDC of nominal voltage peak to peak m F maximum m A maximum VDC minimum at 10 mA VDC minimum at 100 mA current must be limited to 100 mA maximum by the panel The optional RA400Z Remote Annunciator within the specified detector alarm currents VDC minimum seconds maximum seconds maximum after 60 second reset Installing thoroughly read the System Sensor manual I56 407 Guide for Proper Use of System Smoke Detectors which detailed information on detector spacing place zoning wiring and special applications Copies of manual are available at no charge from System Sensor This manual should be left with the owner user this equipment This sensor must be tested and maintained following NFPA 72 requirements This sensor be cleaned at least once a year Description 1100 is a 2 wire ionization smoke detector that uses a sensing chamber This detector is designed provide open area protection and to be used with com UL listed 2 wire panels only of these detectors is simplified by the use of an bracket and a plug in screw terminal block that can prewired to the system allowing the detector to be eas installed or removed for cleaning The detector sensi can be tested in place using the MOD400R Test LED on the detector provides a local visual indication of detector status If power is applied to the detector and is functioning normally in standby the status LED blinks five seconds The LED also latches on in alarm 1100 features a visual indication that maintenance is if the sensing chamber drifts out of its sensitivity the LED ceases to blink detector also includes an output that allows an op RA400Z Remote Annunciator to be connected Manuals Online 1 Surface mounting of 1100 detector on and 4 inch octagonal box 2 Model 1100 detector mounting bracket RESISTANT TAB cid 13 OFF SMALL TAB TO cid 13 TAMPER RESIST cid 13 ARROWS 1100 detector is supplied with a mounting bracket that the detector to be mounted To a single gang box or Directly to a 3 1 2 inch or 4 inch octagonal box or To a 4 inch square electrical box by using a plaster ring Installation Guidelines wiring must be installed in compliance with the Na Electrical Code applicable local codes and any spe requirements of the local authority having jurisdiction wire gauges should be used The conductors used to smoke detectors to control panels and accessory should be color coded to reduce the likelihood of errors Improper connections can prevent a system responding properly in the event of a fire screw terminal block accepts 14 22 gauge wire For system performance all wiring should be installed in grounded conduit Do not mix fire system wiring the same conduit as any other electrical wiring Twisted may be used to provide additional protection against interference detectors and alarm system control panels have for allowable loop resistance Consult the panel specifications for the total loop resistance al for the control panel being used before wiring detec loops connections are made by stripping about 1 4 inch of from the end of the feed wire inserting the wire the appropriate terminal and tightening the screw to the wire in place Sensor smoke detectors are marked with a compat identifier located as the last digit of a five digit code on the back of the product Connect detectors only compatible control units as indicated in System Sensor chart which contains a current list of UL compatible control units and detectors A copy of this is available from System Sensor upon request Feature detector includes a tamper resistant capability that its removal from the bracket without the use of a To make the detector tamper resistant remove the tab by breaking it at the scribed line on the tamper tab on the detector mounting bracket see Figure then install the detector To remove the detector from bracket once it has been made tamper resistant use a screwdriver to depress the tamper resistant tab lo in the slot on the mounting bracket and turn the de counterclockwise 3 Wiring diagram for the 1100 smoke detector LISTED cid 13 RESISTOR cid 13 BY cid 13 Manuals Online CLASS A WIRING the power to the alarm system control unit be installing detectors Wire the plug in screw terminal block per Figure 3 and the terminal block into the detector Align the arrows on the detector with the arrows on the Rotate the detector clockwise in the mounting bracket Test Switch bracket it clicks into place After all detectors have been installed apply power to See Figure 4 control unit or initiating device circuits Test the detector as described in the following para Reset the detector at the system control panel Notify the proper authorities the system is in operation covers are an effective way to limit the entry of dust smoke detector sensing chambers However they may completely prevent airborne dust particles from enter the detector Therefore System Sensor recommends the of detectors before beginning construction or other producing activity Be sure to remove dust covers from sensors that were left in place during construction as of returning the system to service Before testing notify the proper authorities that smoke detector system is undergoing mainte and therefore will be temporarily out of Disable the zone or system undergoing to prevent unwanted alarms must be tested after installation and following maintenance Test the 1100 as follows A recessed test switch is located on the detector hous Push and hold the recessed test switch with a 0.1 inch diameter tool such as an allen wrench or screwdriver The detector LED should light within 5 seconds Test Module System Sensor Model No MOD400R MOD400R test module can be used with a DMM or voltmeter to check the detector sensitivity as de in the test module manual Smoke Entry Test a smoldering punk stick or cotton wick at the side the detector and gently blow smoke through the de until the unit alarms detector that fails to activate with any of the above tests first be cleaned as outlined in MAINTENANCE If detector still fails to activate return it for repair the proper authorities that the system is back in 4 Bottom and side views showing position of test switch MODULE cid 13 TEST cid 13 RECESSED cid 13 WITH A cid 13 MAX DIAMETER TOOL Manuals Online Before removing the detector notify the proper au that the smoke detector system is under maintenance and will temporarily be out of Disable the zone or system undergoing to prevent unwanted alarms Remove the detector housing by